The concentrated load and uniform load shall be uniformly distributed over a 10-foot (3048 mm) width on a line normal to the centerline of the lane placed within a 12-foot-wide (3658 mm) lane. The loads shall be placed within their individual lanes so as to produce the maximum stress in each structural member. Single spans shall be designed for the uniform load in Table 1607.6 and one simultaneous concentrated load positioned to produce the maximum effect. Multiple spans shall be designed for the uniform load in Table 1607.6 on the spans and two simultaneous concentrated loads in two spans positioned to produce the maximum negative moment effect. Multiple span design loads, for other effects, shall be the same as for single spans.

Related Code Sections

1607.6.1 Structural Design, Truck and Bus Garage Live Load Application
The concentrated load and uniform load shall be uniformly distributed over a 10-foot (3048 mm) width on a line normal to the centerline of the lane ...
1607.10 Structural Design, Vehicle Barriers
of ASCE 7. Garages accommodating trucks and buses shall be designed in accordance with an approved method that contains provisions for traffic railings ...
Section 1607 Structural Design, Live Loads
live loads of this Table or the following concentrated loads: (1) for garages restricted to passenger vehicles accommodating not more than nine ...
1607.12.1.3 Structural Design, Passenger Vehicle Garages
The live loads shall not be reduced in passenger vehicle garages. Exception: The live loads for members supporting two or more floors are permitted ...
1607.9.1.3 Structural Design, Passenger Vehicle Garages
The live loads shall not be reduced in passenger vehicle garages. Exception: The live loads for members supporting two or more floors ...