1910.265(e)(4) Trimmer Saws
JUMP TO FULL CODE CHAPTER
—
Trimmer saws shall not be run at peripheral speeds in excess of those recommended by the manufacturer.
Automatic trimmer saws shall be provided with safety stops or hangers to prevent saws from dropping on table.
Trimmer saws shall be guarded in front by adequate baffles to protect against flying debris and they shall be securely bolted to a substantial frame. These guards for a series of saws shall be set as close to the top of the trimmer table as is practical.
The end saws on trimmer shall be guarded.
The rear of trimmer saws shall have a guard the full width of the saws and as much wider as practical.
Related Code Sections
1910.265(e)(4) Special Industries, Trimmer Saws
— Trimmer saws shall not be run at peripheral ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(4) Trimmer Saws
1910.265(e)(4)(ii)(b) Special Industries,
The end saws on trimmer shall be guarded ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(4) Trimmer Saws > 1910.265(e)(4)(ii) Guards > 1910.265(e)(4)(ii)(b)
1910.265(e) Special Industries, Log Breakdown and Related Machinery and Facilities
Automatic trimmer saws shall be provided with safety stops or hangers to prevent ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities
1910.243(a)(2)(iii)(a) Hand and Portable Powered Tools and Other Hand-Held Equipment,
with discs 2 inches in diameter or less, routers, planers, laminate trimmers, nibblers, shears, saber, scroll, and jig saws with blade shanks a nominal one ...
OSHA 1910 General Industry > P Hand and Portable Powered Tools and Other Hand-Held Equipment > 1910.243 Guarding of Portable Powered Tools > 1910.243(a) Portable Powered Tool > 1910.243(a)(2) Switches and Controls > 1910.243(a)(2)(ii) > 1910.243(a)(2)(iii)(a)
1910.243(a)(2)(ii) Hand and Portable Powered Tools and Other Hand-Held Equipment,
sanders with discs greater than 2 inches in diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than ...
OSHA 1910 General Industry > P Hand and Portable Powered Tools and Other Hand-Held Equipment > 1910.243 Guarding of Portable Powered Tools > 1910.243(a) Portable Powered Tool > 1910.243(a)(2) Switches and Controls > 1910.243(a)(2)(ii)