• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.266(h) Tree Harvesting

OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(h) Tree Harvesting
JUMP TO FULL CODE CHAPTER
-

1910.266(h)(1) General Requirements

1910.266(h)(1)(i)

Trees shall not be felled in a manner that may create a hazard for an employee, such as but not limited to, striking a rope, cable, power line, or machine.

1910.266(h)(1)(iii)

While manual felling is in progress, no yarding machine shall be operated within two tree lengths of trees being manually felled. Exception: This provision does not apply to yarding machines performing tree pulling operations.

1910.266(h)(1)(iv)

No employee shall approach a feller closer than two tree lengths of trees being felled until the feller has acknowledged that it is safe to do so, unless the employer demonstrates that a team of employees is necessary to manually fell a particular tree.

1910.266(h)(1)(ix)

Domino felling of trees is prohibited.

Note to paragraph (h)(1)(ix): The definition of domino felling does not include the felling of a single danger tree by felling another single tree into it.

1910.266(h)(1)(v)

No employee shall approach a mechanical felling operation closer than two tree lengths of the trees being felled until the machine operator has acknowledged that it is safe to do so.

1910.266(h)(1)(vi)

Each danger tree shall be felled, removed or avoided. Each danger tree, including lodged trees and snags, shall be felled or removed using mechanical or other techniques that minimize employee exposure before work is commenced in the area of the danger tree. If the danger tree is not felled or removed, it shall be marked and no work shall be conducted within two tree lengths of the danger tree unless the employer demonstrates that a shorter distance will not create a hazard for an employee.

1910.266(h)(1)(vii)

Each danger tree shall be carefully checked for signs of loose bark, broken branches and limbs or other damage before they are felled or removed. Accessible loose bark and other damage that may create a hazard for an employee shall be removed or held in place before felling or removing the tree.

1910.266(h)(1)(viii)

Felling on any slope where rolling or sliding of trees or logs is reasonably foreseeable shall be done uphill from, or on the same level as, previously felled trees.

1910.266(h)(1)(ii)

The immediate supervisor shall be consulted when unfamiliar or unusually hazardous conditions necessitate the supervisor's approval before cutting is commenced.

1910.266(h)(2) Manual Felling

1910.266(h)(2)(i)

Before felling is started, the feller shall plan and clear a retreat path. The retreat path shall extend diagonally away from the expected felling line unless the employer demonstrates that such a retreat path poses a greater hazard than an alternate path. Once the backcut has been made the feller shall immediately move a safe distance away from the tree on the retreat path.

1910.266(h)(2)(iii)

Each tree shall be checked for accumulations of snow and ice. Accumulations of snow and ice that may create a hazard for an employee shall be removed before felling is commenced in the area or the area shall be avoided.

1910.266(h)(2)(iv)

When a spring pole or other tree under stress is cut, no employee other than the feller shall be closer than two trees lengths when the stress is released.

1910.266(h)(2)(v)

An undercut shall be made in each tree being felled unless the employer demonstrates that felling the particular tree without an undercut will not create a hazard for an employee. The undercut shall be of a size so the tree will not split and will fall in the intended direction.

1910.266(h)(2)(vi)

A backcut shall be made in each tree being felled. The backcut shall leave sufficient hinge wood to hold the tree to the stump during most of its fall so that the hinge is able to guide the tree's fall in the intended direction.

1910.266(h)(2)(vii)

The backcut shall be above the level of the horizontal facecut in order to provide an adequate platform to prevent kickback. Exception: The backcut may be at or below the horizontal facecut in tree pulling operations.

Note to paragraph (h)(2)(vii):This requirement does not apply to open face felling where two angled facecuts rather than a horizontal facecut are used.

1910.266(h)(2)(ii)

Before each tree is felled, conditions such as, but not limited to, snow and ice accumulation, the wind, the lean of tree, dead limbs, and the location of other trees, shall be evaluated by the feller and precautions taken so a hazard is not created for an employee.

1910.266(h)(3) Limbing and Bucking

1910.266(h)(3)(i)

Limbing and bucking on any slope where rolling or sliding of trees or logs is reasonably foreseeable shall be done on the uphill side of each tree or log.

1910.266(h)(3)(ii)

Before bucking or limbing wind-thrown trees, precautions shall be taken to prevent the root wad, butt or logs from striking an employee. These precautions include, but are not limited to, chocking or moving the tree to a stable position.

1910.266(h)(4) Chipping (In-Woods Locations)

1910.266(h)(4)(i)

Chipper access covers or doors shall not be opened until the drum or disc is at a complete stop.

1910.266(h)(4)(iii)

The chipper shall be shut down and locked out in accordance with the requirements of 29 CFR 1910.147 when an employee performs any servicing or maintenance.

1910.266(h)(4)(iv)

Detached trailer chippers shall be chocked during usage on any slope where rolling or sliding of the chipper is reasonably foreseeable.

1910.266(h)(4)(ii)

Infeed and discharge ports shall be guarded to prevent contact with the disc, knives, or blower blades.

1910.266(h)(5) Yarding

1910.266(h)(5)(i)

No log shall be moved until each employee is in the clear.

1910.266(h)(5)(iii)

Each choker shall be positioned near the end of the log or tree length.

1910.266(h)(5)(iv)

Each machine shall be positioned during winching so the machine and winch are operated within their design limits.

1910.266(h)(5)(ix)

Each yarded tree shall be placed in a location that does not create a hazard for an employee and an orderly manner so that the trees are stable before bucking or limbing is commenced.

1910.266(h)(5)(v)

No yarding line shall be moved unless the yarding machine operator has clearly received and understood the signal to do so. When in doubt, the yarding machine operator shall repeat the signal and wait for a confirming signal before moving any line.

1910.266(h)(5)(vi)

No load shall exceed the rated capacity of the pallet, trailer, or other carrier.

1910.266(h)(5)(vii)

Towed equipment, such as but not limited to, skid pans, pallets, arches, and trailers, shall be attached to each machine or vehicle in such a manner as to allow a full 90 degree turn; to prevent overrunning of the towing machine or vehicle; and to assure that the operator is always in control of the towed equipment.

1910.266(h)(5)(viii)

The yarding machine or vehicle, including its load, shall be operated with safe clearance from all obstructions that may create a hazard for an employee.

1910.266(h)(5)(ii)

Each choker shall be hooked and unhooked from the uphill side or end of the log, unless the employer demonstrates that is it not feasible in the particular situation to hook or unhook the choker from the uphill side. Where the choker is hooked or unhooked from the downhill side or end of the log, the log shall be securely chocked to prevent rolling, sliding or swinging.

1910.266(h)(6) Loading and Unloading

1910.266(h)(6)(i)

The transport vehicle shall be positioned to provide working clearance between the vehicle and the deck.

1910.266(h)(6)(iii)

No transport vehicle operator shall remain in the cab during loading and unloading if the logs are carried or moved over the truck cab, unless the employer demonstrates that it is necessary for the operator to do so. Where the transport vehicle operator remains in the cab, the employer shall provide operator protection, such as but not limited to, reinforcement of the cab.

1910.266(h)(6)(iv)

Each log shall be placed on a transport vehicle in an orderly manner and tightly secured.

1910.266(h)(6)(v)

The load shall be positioned to prevent slippage or loss during handling and transport.

1910.266(h)(6)(vi)

Each stake and chock which is used to trip loads shall be so constructed that the tripping mechanism is activated on the side opposite the release of the load.

1910.266(h)(6)(vii)

Each tie down shall be left in place over the peak log to secure all logs until the unloading lines or other protection the employer demonstrates is equivalent has been put in place. A stake of sufficient strength to withstand the forces of shifting or moving logs, shall be considered equivalent protection provided that the logs are not loaded higher than the stake.

1910.266(h)(6)(viii)

Each tie down shall be released only from the side on which the unloading machine operates, except as follows:

1910.266(h)(6)(viii)(A)

When the tie down is released by a remote control device; and

1910.266(h)(6)(viii)(B)

When the employee making the release is protected by racks, stanchions or other protection the employer demonstrates is capable of withstanding the force of the logs.

1910.266(h)(6)(ii)

Only the loading or unloading machine operator and other personnel the employer demonstrates are essential shall be in the loading or unloading work area during this operation.

1910.266(h)(7) Transport

The transport vehicle operator shall assure that each tie down is tight before transporting the load. While enroute, the operator shall check and tighten the tie downs whenever there is reason to believe that the tie downs have loosened or the load has shifted.

1910.266(h)(8) Storage

Each deck shall be constructed and located so it is stable and provides each employee with enough room to safely move and work in the area.

Related Code Sections


1910.266(h) Special Industries, Tree Harvesting
- Trees ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(h) Tree Harvesting
1910.266(h)(6) Special Industries, Loading and Unloading
The transport vehicle shall be positioned to provide working clearance between the vehicle and the deck ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(h) Tree Harvesting > 1910.266(h)(6) Loading and Unloading
1910.266(h)(7) Special Industries, Transport
The transport vehicle operator shall assure that each tie down is tight before transporting the load. While enroute, the operator shall check ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(h) Tree Harvesting > 1910.266(h)(7) Transport
1910.266(h)(8) Special Industries, Storage
Each deck shall be constructed and located so it is stable and provides each employee with enough room to safely move and work in the area ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(h) Tree Harvesting > 1910.266(h)(8) Storage
1910.266(h)(5)(ix) Special Industries,
Each yarded tree shall be placed in a location that does not create a hazard for an employee and an orderly manner so that the trees are stable ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(h) Tree Harvesting > 1910.266(h)(5) Yarding > 1910.266(h)(5)(ix)
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE