1030.14.2.1 Treads
JUMP TO FULL CODE CHAPTER
Tread depths shall be not less than 11 inches (279 mm) and shall have dimensional uniformity.
Exception: The tolerance between adjacent treads shall not exceed 3/16 inch (4.8 mm).
Related Code Sections
1029.14.2.1 Means of Egress, Treads
Tread depths shall be not less than 11 inches (279 mm) and shall have dimensional uniformity. Exception: The tolerance between adjacent treads ...
Building Code 2018 of Illinois > 10 Means of Egress > 1029 Assembly > 1029.14 Assembly Aisle Walking Surfaces > 1029.14.2 Stepped Aisles > 1029.14.2.1 Treads
1030.14.2.1 Means of Egress, Treads
Tread depths shall be not less than 11 inches (279 mm) and shall have dimensional uniformity. Exception: The tolerance between adjacent treads ...
Building Code 2021 of Illinois > 10 Means of Egress > 1030 Assembly > 1030.14 Assembly Aisle Walking Surfaces > 1030.14.2 Stepped Aisles > 1030.14.2.1 Treads
1011.14.2 Means of Egress, Treads of Alternating Tread Devices
Alternating tread devices shall have a minimum tread depth of 5 inches (127 mm), a minimum projected tread depth of 8 1 / 2 inches (216 mm ...
Building Code 2021 of Illinois > 10 Means of Egress > 1011 Stairways > 1011.14 Alternating Tread Devices > 1011.14.2 Treads of Alternating Tread Devices
1011.14.2 Means of Egress, Treads of Alternating Tread Devices
Alternating tread devices shall have a minimum tread depth of 5 inches (127 mm), a minimum projected tread depth of 8 1 / 2 inches (216 mm ...
Building Code 2018 of Illinois > 10 Means of Egress > 1011 Stairways > 1011.14 Alternating Tread Devices > 1011.14.2 Treads of Alternating Tread Devices
1017.5 Recreation Facilities, Tread Obstacles
Tread obstacles on trails, passing spaces, and resting intervals shall not exceed 1 / 2 inch (13 mm) in height measured vertically to the highest ...