The plumbing system shall be provided with a system of vent piping that will allow the admission or emission of air so that the liquid seal of any fixture trap shall not be subjected to a pressure differential of more than 1 inch of water column (249 Pa).
P3101.2.1 Venting Required
Every trap and trapped fixture shall be vented in accordance with one of the venting methods specified in this chapter.

Related Code Sections

P3201.2.1 Traps, Trap Seal Protection
Traps seals of emergency floor drain traps and traps subject to evaporation shall be protected by one of the methods in Sections P3201.2.1.1 through ...
P3201.2.1 Traps, Trap Seal Protection
Traps seals of emergency floor drain traps and traps subject to evaporation shall be protected by one of the methods in Sections P3201.2.1.1 ...
1002.4.1 Traps, Interceptors and Separators, Trap Seal Protection
Trap seals of emergency floor drain traps and trap seals subject to evaporation shall be protected by one of the methods in Sections 1002.4.1.1 ...
901.2 Vents, Trap Seal Protection
The plumbing system shall be provided with a system of vent piping that will permit the admission or emission of air so that the seal of any fixture ...
P3101.2 Vents, Trap Seal Protection
The plumbing system shall be provided with a system of vent piping that will allow the admission or emission of air so that the liquid seal of any ...