• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.109(d) Transportation of Explosives

OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(d) Transportation of Explosives
JUMP TO FULL CODE CHAPTER

1910.109(d)(1) General Provisions

1910.109(d)(1)(i)

No employee shall be allowed to smoke, carry matches or any other flame-producing device, or carry any firearms or loaded cartridges while in or near a motor vehicle transporting explosives; or drive, load, or unload such vehicle in a careless or reckless manner.

1910.109(d)(1)(iii)

Explosives shall not be transferred from one vehicle to another within the confines of any jurisdiction (city, county, State, or other area) without informing the fire and police departments thereof. In the event of breakdown or collision the local fire and police departments shall be promptly notified to help safeguard such emergencies. Explosives shall be transferred from the disabled vehicle to another only, when proper and qualified supervision is provided.

1910.109(d)(1)(iv)

Blasting caps or electric blasting caps shall not be transported over the highways on the same vehicles with other explosives, unless packaged, segregated, and transported in accordance with the Department of Transportation's Hazardous Materials Regulations (49 CFR parts 177-180).

1910.109(d)(1)(ii) [Reserved]

1910.109(d)(2) Transportation Vehicles

1910.109(d)(2)(i)

Vehicles used for transporting explosives shall be strong enough to carry the load without difficulty and be in good mechanical condition. If vehicles do not have a closed body, the body shall be covered with a flameproof and moistureproof tarpaulin or other effective protection against moisture and sparks. All vehicles used for the transportation of explosives shall have tight floors and any exposed spark-producing metal on the inside of the body shall be covered with wood or other nonsparking materials to prevent contact with packages of explosives. Packages of explosives shall not be loaded above the sides of an open-body vehicle.

1910.109(d)(2)(iii)

Each motor vehicle used for transporting explosives shall be equipped with a minimum of two extinguishers, each having a rating of at least 10-BC.

1910.109(d)(2)(iii)(a)

Only extinguishers listed or approved by a nationally recognized testing laboratory shall be deemed suitable for use on explosives-carrying vehicles. Refer to 1910.155(c)(3)(iv)(A) for definition of listed and 1910.7 for nationally recognized testing laboratory.

1910.109(d)(2)(iii)(b)

Extinguishers shall be filled and ready for immediate use and located near the driver's seat. Extinguishers shall be examined periodically by a competent person.

1910.109(d)(2)(iv)

A motor vehicle used for transporting explosives shall be given the following inspection to determine that it is in proper condition for safe transportation of explosives:

1910.109(d)(2)(iv)(a)

Fire extinguishers shall be filled and in working order.

1910.109(d)(2)(iv)(b)

All electrical wiring shall be completely protected and securely fastened to prevent short-circuiting.

1910.109(d)(2)(iv)(c)

Chassis, motor, pan, and underside of body shall be reasonably clean and free of excess oil and grease.

1910.109(d)(2)(iv)(d)

Fuel tank and feedline shall be secure and have no leaks.

1910.109(d)(2)(iv)(e)

Brakes, lights, horn, windshield wipers, and steering apparatus shall function properly.

1910.109(d)(2)(iv)(f)

Tires shall be checked for proper inflation and defects.

1910.109(d)(2)(iv)(g)

The vehicle shall be in proper condition in every other respect and acceptable for handling explosives.

1910.109(d)(2)(ii)

Every vehicle used for transporting explosives and oxidizing materials listed in paragraph (d)(2)(ii)(a) of this section shall be marked as follows:

1910.109(d)(2)(ii)(a)

Exterior markings or placards required on applicable vehicles shall be as follows for the various classes of commodities:

Commodity Type of marking or placard
Explosives, Class A, any quantity
or a combination of Class A and
Class B explosives.
Explosives A (Red letters
on white background).
Explosives, Class B, and quantity.
Explosives B (Red letters
on white background).
Oxidizing material (blasting
agents, ammonium nitrate, etc.),
1,000 pounds or more gross
weight.
Oxidizers (Yellow letters
on black background).

1910.109(d)(2)(ii)(b) [Reserved]

1910.109(d)(2)(ii)(c)

Such markings or placards shall be displayed at the front, rear, and on each side of the motor vehicle or trailer, or other cargo carrying body while it contains explosives or other dangerous articles of such type and in such quantity as specified in paragraph (d)(1)(ii)(a) of this subdivision. The front marking or placard may be displayed on the front of either the truck, truck body, truck tractor or the trailer.

1910.109(d)(2)(ii)(d)

Any motor vehicle, trailer, or other cargo-carrying body containing more than one kind of explosive as well as an oxidizing material requiring a placard under the provisions of paragraph (d)(2)(ii)(a), the aggregate gross weight of which totals 1,000 pounds or more, shall be marked or placarded "Dangerous" as well as "Explosive A" or "Explosive B" as appropriate. If explosives Class A and explosives Class B are loaded on the same vehicle, the "Explosives B" marking need not be displayed.

1910.109(d)(2)(ii)(e)

In any combination of two or more vehicles containing explosives or other dangerous articles each vehicle shall be marked or placarded as to its contents and in accordance with paragraphs (d)(2)(ii) (a) and (c) of this subdivision.

1910.109(d)(3) Operation of Transportation Vehicles

1910.109(d)(3)(i)

Vehicles transporting explosives shall only be driven by and be in the charge of a driver who is familiar with the traffic regulations, State laws, and the provisions of this section.

1910.109(d)(3)(iii)

Every motor vehicle transporting any quantity of Class A or Class B explosives shall, at all times, be attended by a driver or other attendant of the motor carrier. This attendant shall have been made aware of the class of the explosive material in the vehicle and of its inherent dangers, and shall have been instructed in the measures and procedures to be followed in order to protect the public from those dangers. He shall have been made familiar with the vehicle he is assigned, and shall be trained, supplied with the necessary means, and authorized to move the vehicle when required.

1910.109(d)(3)(iii)(a)

For the purpose of this subdivision, a motor vehicle shall be deemed "attended" only when the driver or other attendant is physically on or in the vehicle, or has the vehicle within his field of vision and can reach it quickly and without any kind of interference "attended" also means that the driver or attendant is awake, alert, and not engaged in other duties or activities which may divert his attention from the vehicle, except for necessary communication with public officers, or representatives of the carrier shipper, or consignee, or except for necessary absence from the vehicle to obtain food or to provide for his physical comfort.

1910.109(d)(3)(iii)(b)

However, an explosive-laden vehicle may be left unattended if parked within a securely fenced or walled area with all gates or entrances locked where parking of such vehicle is otherwise permissible, or at a magazine site established solely for the purpose of storing explosives.

1910.109(d)(3)(iv)

No spark-producing metal, spark-producing metal tools, oils, matches, firearms, electric storage batteries, flammable substances, acids, oxidizing materials, or corrosive compounds shall be carried in the body of any motor truck and/or vehicle transporting explosives, unless the loading of such dangerous articles and the explosives comply with U.S. Department of Transportation regulations.

1910.109(d)(3)(v)

Vehicles transporting explosives shall avoid congested areas and heavy traffic. Where routes through congested areas have been designated by local authorities such routes shall be followed.

1910.109(d)(3)(vi)

Delivery shall only be made to authorized persons and into authorized magazines or authorized temporary storage or handling areas.

1910.109(d)(3)(ii)

Except under emergency conditions, no vehicle transporting explosives shall be parked before reaching its destination, even though attended, on any public street adjacent to or in proximity to any place where people work.

Related Code Sections


1910.109(d) Hazardous Materials, Transportation of Explosives
a motor vehicle transporting explosives; or drive, load, or unload such vehicle in a careless or reckless manner ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(d) Transportation of Explosives
1910.109(d)(2)(ii)(a) Hazardous Materials,
: Commodity Type of marking or placard Explosives, Class A, any quantity or a combination of Class A and Class B explosives ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(d) Transportation of Explosives > 1910.109(d)(2) Transportation Vehicles > 1910.109(d)(2)(ii) > 1910.109(d)(2)(ii)(a)
1910.109(d)(2)(ii)(b) Hazardous Materials, [Reserved]
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(d) Transportation of Explosives > 1910.109(d)(2) Transportation Vehicles > 1910.109(d)(2)(ii) > 1910.109(d)(2)(ii)(b) [Reserved]
1910.109(d)(2)(ii)(c) Hazardous Materials,
it contains explosives or other dangerous articles of such type and in such quantity as specified in paragraph (d)(1)(ii)(a) of this subdivision. The ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(d) Transportation of Explosives > 1910.109(d)(2) Transportation Vehicles > 1910.109(d)(2)(ii) > 1910.109(d)(2)(ii)(c)
1910.109(d)(2)(ii)(d) Hazardous Materials,
Any motor vehicle, trailer, or other cargo-carrying body containing more than one kind of explosive as well as an oxidizing material requiring ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(d) Transportation of Explosives > 1910.109(d)(2) Transportation Vehicles > 1910.109(d)(2)(ii) > 1910.109(d)(2)(ii)(d)
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING