• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section E109 Transportation Facilities and Stations

NYC Building Code 2014 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations
JUMP TO FULL CODE CHAPTER

E109.1 General

Fixed transportation facilities and stations shall comply with the applicable provisions of Section E109.2.

E109.2 New Construction

New stations in rapid rail, light rail, commuter rail, intercity rail, high speed rail and other fixed guideway systems shall comply with Sections E109.2.1 through E109.2.8.

E109.2.1 Station Entrances

Where different entrances to a station serve different transportation fixed routes or groups of fixed routes, all entrance serving each group or route shall comply with Section 1104 and ICC A117.1, including Section 404 (Doors and Doorways).

E109.2.2 Signs

Signage in fixed transportation facilities and stations shall comply with Sections E109.2.2.1 through E109.2.2.3.

E109.2.2.1 Tactile Signs

Where signs are provided at entrances to stations identifying the station or the entrance, or both, at least one sign at each entrance shall be tactile. A minimum of one tactile sign identifying the specific station shall be provided on each platform or boarding area. Such signs shall be placed in uniform locations at entrances and on platforms or boarding areas within the transit system to the maximum extent practicable. Tactile signs shall comply with Section 703.3 (Tactile Characters) of ICC A117.1.

Exceptions:
  1. Where the station has no defined entrance but signs are provided, the tactile signs shall be placed in a central location.
  2. Signs are not required to be tactile where audible signs are remotely transmitted to hand-held receivers, or are user or proximity actuated.

E109.2.2.2 Identification Signs

Stations covered by this section shall have identification signs containing visual characters complying with Section 703.2 (Visual Characters) of ICC A117.1. Signs shall be clearly visible and within the sightlines of a standing or sitting passenger from within the train on both sides when not obstructed by another train.

E109.2.2.3 Informational Signs

Lists of stations, routes and destinations served by the station which are located on boarding areas, platforms or mezzanines shall provide visual characters complying with Section 703.2 (Visual Characters) of ICC A117.1. Signs covered by this provision shall, to the maximum extent practicable, be placed in uniform locations within the transit system.

E109.2.3 Fare Machines

Self-service fare vending, collection and adjustment machines shall comply with Section 707 (ATMs and Fare Machines) of ICC A117.1. Where self-service fare vending, collection or adjustment machines are provided for the use of the general public, at least one accessible machine of each type provided shall be provided at each accessible point of entry and exit.

E109.2.4 Rail-To-Platform Height

Station platforms shall be positioned to coordinate with vehicles in accordance with the applicable provisions of 36 CFR, Part 1192. Low-level platforms shall be 8 inches (203 mm) minimum above top of rail.

Exception: Where vehicles are boarded from sidewalks or street level, low-level platforms shall be permitted to be less than 8 inches (203 mm).

E109.2.5 TTYs

Where a public pay telephone is provided in a transit facility (as defined by the Department of Transportation) at least one public TTY complying with Sections 704.4 through 704.7 of ICC A117.1 shall be provided in the station. In addition, where one or more public pay telephones serve a particular entrance to a transportation facility, at least one TTY telephone complying with Section 704.4 through 704.7 of ICC A117.1 shall be provided to serve that entrance.

E109.2.6 Track Crossings

Where a circulation path serving boarding platforms crosses tracks, an accessible route complying with ICC A117.1, including Section 402 (Accessible Routes) shall be provided.

Exception: Openings for wheel flanges shall be permitted to be 21/2 inches (64 mm) maximum.

E109.2.7 Public Address Systems

Where public address systems convey audible information to the public, the same or equivalent information shall be provided in a visual format.

E109.2.8 Clocks

Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands, numerals and digits shall contrast with the background either light-on-dark or dark-on-light. Where clocks are mounted overhead, numerals and digits shall comply with Section 703.2 (Visual Characters) of ICC A117.1.

E109.3 Reserved

Related Code Sections


Section E109 Supplementary Accessibility Requirements, Transportation Facilities and Stations
Fixed transportation facilities and stations shall comply with the applicable provisions of Section E109.2 ...
NYC Building Code 2014 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations
Section E109 Supplementary Accessibility Requirements, Transportation Facilities and Stations
Fixed transportation facilities and stations shall comply with the applicable provisions of Section E109.2 ...
NYC Building Code 2008 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations
E109.3 Supplementary Accessibility Requirements, Reserved
NYC Building Code 2008 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations > E109.3 Reserved
E109.2.1 Supplementary Accessibility Requirements, Station Entrances
Where different entrances to a station serve different transportation fixed routes or groups of fixed routes, all entrance serving each group ...
NYC Building Code 2014 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations > E109.2 New Construction > E109.2.1 Station Entrances
E109.2.1 Supplementary Accessibility Requirements, Station Entrances
Where different entrances to a station serve different transportation fixed routes or groups of fixed routes, all entrance serving each group ...
NYC Building Code 2008 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations > E109.2 New Construction > E109.2.1 Station Entrances
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE