• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

M1502.4.3 Transition Duct

Residential Code 2018 of Kansas > 15 Exhaust Systems > M1502 Clothes Dryer Exhaust > M1502.4 Dryer Exhaust Ducts > M1502.4.3 Transition Duct
JUMP TO FULL CODE CHAPTER
Transition ducts used to connect the dryer to the exhaust duct system shall be a single length that is listed and labeled in accordance with UL 2158A. Transition ducts shall be not greater than 8 feet (2438 mm) in length. Transition ducts shall not be concealed within construction.

Related Code Sections


504.8.3 Exhaust Systems, Transition Ducts
Transition ducts used to connect the dryer to the exhaust duct system shall be a single length that is listed and labeled in accordance with UL ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.8 Domestic Clothes Dryer Ducts > 504.8.3 Transition Ducts
614.8.3 Specific Appliances, Transition Ducts
Transition ducts used to connect the dryer to the exhaust duct system shall be a single length that is listed and labeled in accordance with UL ...
Fuel Gas Code 2018 of Kansas > 6 Specific Appliances > 614 (IFGC) Clothes Dryer Exhaust > 614.8 Domestic Clothes Dryer Exhaust Ducts > 614.8.3 Transition Ducts
M1502.4.3 Exhaust Systems, Transition Duct
Transition ducts used to connect the dryer to the exhaust duct system shall be a single length that is listed and labeled in accordance with UL ...
Residential Code 2018 of Kansas > 15 Exhaust Systems > M1502 Clothes Dryer Exhaust > M1502.4 Dryer Exhaust Ducts > M1502.4.3 Transition Duct
G2439.7.3 Fuel Gas, (614.8.3) Transition Ducts
Transition ducts used to connect the dryer to the exhaust duct system shall be a single length that is listed and labeled in accordance with UL 2158A ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2439 (614) Clothes Dryer Exhaust > G2439.7 (614.8) Domestic Clothes Dryer Exhaust Ducts > G2439.7.3 (614.8.3) Transition Ducts
504.8 Exhaust Systems, Domestic Clothes Dryer Ducts
Transition ducts used to connect the dryer to the exhaust duct system shall be a single length that is listed ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.8 Domestic Clothes Dryer Ducts
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE