• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5706.4.7.2 Transferring Location

Minnesota Fire Code 2015 > 57 Flammable and Combustible Liquids > 5706 Special Operations > 5706.4 Bulk Plants or Terminals > 5706.4.7 Wharves > 5706.4.7.2 Transferring Location
JUMP TO FULL CODE CHAPTER
Wharves at which liquid cargoes are to be transferred in bulk quantities to or from tank vessels shall be at least 100 feet (30 480 mm) from any bridge over a navigable waterway; or from an entrance to, or superstructure of, any vehicular or railroad tunnel under a waterway. The termination of the fixed piping used for loading or unloading at a wharf shall be at least 200 feet (60 960 mm) from a bridge or from an entrance to, or superstructures of, a tunnel.

Related Code Sections


5706.4.7.2 Flammable and Combustible Liquids, Transferring Location
Wharves at which liquid cargoes are to be transferred in bulk quantities to or from tank vessels shall be not less than 100 feet (30 480 mm) from any ...
2020 Minnesota State Fire Code > 57 Flammable and Combustible Liquids > 5706 Special Operations > 5706.4 Bulk Plants or Terminals > 5706.4.7 Wharves > 5706.4.7.2 Transferring Location
5706.4.7.2 Flammable and Combustible Liquids, Transferring Location
Wharves at which liquid cargoes are to be transferred in bulk quantities to or from tank vessels shall be at least 100 feet (30 480 mm) from any ...
Minnesota Fire Code 2015 > 57 Flammable and Combustible Liquids > 5706 Special Operations > 5706.4 Bulk Plants or Terminals > 5706.4.7 Wharves > 5706.4.7.2 Transferring Location
2006.17 Aviation Facilities, Fuel-Transfer Locations
Aircraft fuel-transfer operations shall be prohibited indoors. Exception: In aircraft hangars built in accordance with the provisions ...
Minnesota Fire Code 2015 > 20 Aviation Facilities > 2006 Aircraft Fueling > 2006.17 Fuel-Transfer Locations
2006.17 Aviation Facilities, Fuel-Transfer Locations
Aircraft fuel-transfer operations shall be prohibited indoors. Exception: In aircraft hangars built in accordance with the provisions ...
2020 Minnesota State Fire Code > 20 Aviation Facilities > 2006 Aircraft Fueling > 2006.17 Fuel-Transfer Locations
5706.5.1.5 Flammable and Combustible Liquids, Spill Control and Secondary Containment
Areas where transfer operations are located shall be provided with spill control and secondary containment in accordance with Section 5703.4. The ...
Minnesota Fire Code 2015 > 57 Flammable and Combustible Liquids > 5706 Special Operations > 5706.5 Bulk Transfer and Process Transfer Operations > 5706.5.1 General > 5706.5.1.5 Spill Control and Secondary Containment
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE