1910.107(e)(4) Transferring Liquids
JUMP TO FULL CODE CHAPTER
Except as provided in paragraph (e)(5) of this section the withdrawal of flammable liquids and liquids with a flashpoint greater than 199.4 °F (93 °C) from containers having a capacity of greater than 60 gallons shall be by approved pumps. The withdrawal of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) from containers and the filling of containers, including portable mixing tanks, shall be done only in a suitable mixing room or in a spraying area when the ventilating system is in operation. Adequate precautions shall be taken to protect against liquid spillage and sources of ignition.
Related Code Sections
1910.107(e)(4) Hazardous Materials, Transferring Liquids
Except as provided in paragraph (e)(5) of this section the withdrawal of flammable liquids and liquids with a flashpoint greater than 199.4 °F (93 °C ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.107 Spray Finishing Using Flammable and Combustible Materials > 1910.107(e) Flammable Liquids and Liquids With a Flashpoint Greater Than 199.4 °F (93 °C) > 1910.107(e)(4) Transferring Liquids
1910.110(b)(14) Hazardous Materials, Transfer of Liquids
to the atmosphere at a rate not to exceed that from a No. 31 drill size opening and provided that such venting and liquid transfer shall be located ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.110 Storage and Handling of Liquefied Petroleum Gases > 1910.110(b) Basic Rules > 1910.110(b)(14) Transfer of Liquids
1910.111(b)(12) Hazardous Materials, Transfer of Liquids
Pumps used for transferring ammonia shall be those manufactured for that purpose ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.111 Storage and Handling of Anhydrous Ammonia > 1910.111(b) Basic Rules > 1910.111(b)(12) Transfer of Liquids
1910.110(b)(14)(iv) Hazardous Materials,
Gas or liquid shall not be vented to the atmosphere to assist in transferring contents of one container to another, except as provided in paragraph ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.110 Storage and Handling of Liquefied Petroleum Gases > 1910.110(b) Basic Rules > 1910.110(b)(14) Transfer of Liquids > 1910.110(b)(14)(iv)
1910.111(b)(12)(i) Hazardous Materials,
Anhydrous ammonia shall always be at a temperature suitable for the material of construction and the design of the receiving container ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.111 Storage and Handling of Anhydrous Ammonia > 1910.111(b) Basic Rules > 1910.111(b)(12) Transfer of Liquids > 1910.111(b)(12)(i)