• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.961(c)(9) Transferring Clearances

OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.961 Deenergizing Lines and Equipment for Employee Protection > 1926.961(c) Deenergizing Lines and Equipment > 1926.961(c)(9) Transferring Clearances
JUMP TO FULL CODE CHAPTER
To transfer the clearance, the employee in charge (or the employee's supervisor if the employee in charge must leave the worksite due to illness or other emergency) shall inform the system operator and employees in the crew; and the new employee in charge shall be responsible for the clearance.

Related Code Sections


1926.961(c)(9) Electric Power Transmission and Distribution, Transferring Clearances
To transfer the clearance, the employee in charge (or the employee's supervisor if the employee in charge must leave the worksite due to illness ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.961 Deenergizing Lines and Equipment for Employee Protection > 1926.961(c) Deenergizing Lines and Equipment > 1926.961(c)(9) Transferring Clearances
1926.406(a)(3) Electrical, Clearance
The dimension of the working space in the direction of access to live parts which may require examination, adjustment, servicing, or maintenance while ...
OSHA 1926 Construction > K Electrical > 1926.406 Specific Purpose Equipment and Installations > 1926.406(a) Cranes and Hoists > 1926.406(a)(3) Clearance
1926.154(b) Fire Protection and Prevention, Clearance and Mounting
Temporary heating devices shall be installed to provide clearance to combustible material not less than the amount shown in Table F-4 ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.154 Temporary Heating Devices > 1926.154(b) Clearance and Mounting
1926.403(i)(1)(i) Electrical, Working Clearances
locations other than the back. TABLE K-1 - Working Clearances Nominal voltage to ground Minimum clear ...
OSHA 1926 Construction > K Electrical > 1926.403 General Requirements > 1926.403(i) 600 Volts, Nominal, or Less > 1926.403(i)(1) Working Space About Electric Equipment > 1926.403(i)(1)(i) Working Clearances
1926.66(d)(8) Occupational Health and Environmental Controls, Discharge Clearance
Unless the spray booth exhaust duct terminal is from a water-wash spray booth, the terminal discharge point shall be not less than 6 feet from any ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.66 Criteria for Design and Construction of Spray Booths > 1926.66(d) Ventilation > 1926.66(d)(8) Discharge Clearance
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING