608.2.1 Transfer Type Shower Compartments
Go To Full Code Chapter
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower compartment. Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided.
![]() |
Upcodes Diagrams
Related Code Sections
608.2.1 Plumbing Elements and Facilities, Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing ...
608.2 Plumbing Elements and Facilities, Size and Clearances for Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured ...
608.5 Plumbing Elements and Facilities, Controls
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite ...
610.3 Plumbing Elements and Facilities, Shower Compartment Seats
the adjacent side wall to a point within 3 inches (75 mm) of the compartment entry. In transfer-type showers, the seat shall extend from the back ...
608.3 Plumbing Elements and Facilities, Grab Bars
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from ...