11B-1008.3.2 Transfer Steps
JUMP TO FULL CODE CHAPTER

Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes. Transfer steps shall comply with Section 11B-1008.3.2.
FIGURE 11B-1008.3.2
TRANSFER STEPS
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
Each transfer step shall be 8 inches (203 mm) high maximum.
At least one means of support for transferring shall be provided.
Striping complying with Section 11B-504.4.1 shall be provided at each transfer step.
Related Code Sections
11B-1008.3.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Transfer Steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-1008 Play Areas > 11B-1008.3 Transfer Systems > 11B-1008.3.2 Transfer Steps
11B-1009.5.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Transfer Steps
Transfer step height shall be 8 inches ( 203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches ( 457 mm ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-1009 Swimming Pools, Wading Pools, and Spas > 11B-1009.5 Transfer Systems > 11B-1009.5.4 Transfer Steps
11B-1008.3.2.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Contrasting Stripe
Striping complying with Section 11B -504.4.1 shall be provided at each transfer step ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-1008 Play Areas > 11B-1008.3 Transfer Systems > 11B-1008.3.2 Transfer Steps > 11B-1008.3.2.4 Contrasting Stripe
11B-1008.3.2.1 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Size
Transfer steps shall have level surfaces 14 inches ( 356 mm) deep minimum and 24 inches (610 mm) wide minimum ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-1008 Play Areas > 11B-1008.3 Transfer Systems > 11B-1008.3.2 Transfer Steps > 11B-1008.3.2.1 Size
11B-1009.5.7 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Grab Bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-1009 Swimming Pools, Wading Pools, and Spas > 11B-1009.5 Transfer Systems > 11B-1009.5.7 Grab Bars