1008.3.1.3 Transfer Space
Go To Full Code Chapter
A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform. The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform. The side of the transfer platform serving the transfer space shall be unobstructed.
Related Code Sections
1008.3.1.3 Recreation Facilities, Transfer Space
A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform. The 48 inch (1220 mm) long minimum ...
1009.5.2 Recreation Facilities, Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base ...
1004.1 Recreation Facilities, Clear Floor Space
Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated ...
1009.4 Recreation Facilities, Transfer Walls
of the transfer wall. Where one grab bar is provided, the clear deck space shall be centered on the grab bar. Where two grab bars are provided ...
1002.5 Recreation Facilities, Amusement Ride Seats Designed for Transfer
Designed for Transfer. The proximity of the clear floor or ground space next to an element and the height of the element one is transferring ...