1009.5.1 Transfer Platform
JUMP TO FULL CODE CHAPTER
A transfer platform shall be provided at the head of each transfer system. Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width.
Figure 1009.5.1
Size of Transfer Platform
Size of Transfer Platform
Related Code Sections
1008.3.1 Recreation Facilities, Transfer Platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply ...
Texas Accessibility Standards 2012 > 10 Recreation Facilities > 1008 Play Areas > 1008.3 Transfer Systems > 1008.3.1 Transfer Platforms
1009.5.1 Recreation Facilities, Transfer Platform
A transfer platform shall be provided at the head of each transfer system. Transfer platforms shall provide 19 inches (485 mm) minimum clear depth ...
Texas Accessibility Standards 2012 > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.5 Transfer Systems > 1009.5.1 Transfer Platform
1009.5.2 Recreation Facilities, Transfer Space
of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side of the transfer platform. The side of the transfer platform ...
Texas Accessibility Standards 2012 > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.5 Transfer Systems > 1009.5.2 Transfer Space
1008.3 Recreation Facilities, Transfer Systems
components. Moving between a transfer platform and a series of transfer steps requires extensive exertion for some children. Designers should minimize ...
Texas Accessibility Standards 2012 > 10 Recreation Facilities > 1008 Play Areas > 1008.3 Transfer Systems
1009.5.7 Recreation Facilities, Grab Bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform ...
Texas Accessibility Standards 2012 > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.5 Transfer Systems > 1009.5.7 Grab Bars