23-65 Tower Regulations
Go To Full Code Chapter
See More
R9 R10
In the districts indicated without a letter suffix, except for Quality Housing buildings, and except as set forth in paragraph (c) of this Section, any portion or portions of buildings which in the aggregate occupy not more than 40 percent of the lot area of a zoning lot, or for zoning lots of less than 20,000 square feet, the percentage set forth in the table below, may penetrate an established sky exposure plane in accordance with the provisions of this Section. Such portions of buildings that penetrate a sky exposure plane are hereinafter referred to as towers.
LOT COVERAGE OF TOWERS ON SMALL ZONING LOTS
Area of Zoning Lot (in square feet) | Maximum Percent of Lot Coverage |
10,500 or less | 50 |
10,501 to 11,500 | 49 |
11,501 to 12,500 | 48 |
12,501 to 13,500 | 47 |
13,501 to 14,500 | 46 |
14,501 to 15,500 | 45 |
15,501 to 16,500 | 44 |
16,501 to 17,500 | 43 |
17,501 to 18,500 | 42 |
18,501 to 19,999 | 41 |
Buildings developed or enlarged with towers shall comply with either tower-on-a-base regulations or standard tower regulations, as follows:
- Applicability of tower-on-a-base regulations
The tower-on-a-base regulations of Section 23-651 shall apply to any such building that:- contains more than 25 percent of its total floor area in residential use; and
- is located on a zoning lot that fronts upon a wide street and is either within 125 feet from such wide street frontage along the short dimension of the block or within 100 feet from such wide street frontage along the long dimension of the block.If a portion of such building is developed or enlarged with a tower the entire zoning lot shall be subject to the provisions of Section 23-651 (Tower-on-a-base).
- Applicability of standard tower regulations
The standard tower regulations of Section 23-652 shall apply to any such building that does not meet the location and floor area criteria of paragraph (a) of this Section. - Inapplicability of tower regulations
The provisions of this Section shall not apply to any building located wholly or partly in a Residence District, that is within 100 feet of a public park with an area of one acre or more, or a street line opposite such a public park.
23-651 Tower-on-a-Base
Any development or enlargement that meets the location and floor area criteria of paragraph (a) of Section 23-65 and includes a tower shall be constructed as a tower-on-a-base, in accordance with the regulations set forth in this Section. The height of all buildings or other structures shall be measured from the base plane.
(a) Tower regulations
(1) At any level above a building base (referred to hereinafter as a "base"), any portion or portions of a building (referred to hereinafter as a "tower") shall occupy in the aggregate:
(i) not more than 40 percent of the lot area of a zoning lot or, for a zoning lot of less than 20,000 square feet, the percentage set forth in the table in Section 23-65 (Tower Regulations); and
(ii) not less than 30 percent of the lot area of a zoning lot.
However, the highest four stories of the tower or 40 feet, whichever is less, may cover less than 30 percent of the lot area of a zoning lot if the gross area of each story does not exceed 80 percent of the gross area of that story directly below it.
(2) Any tower located above a base shall not be subject to the provisions of Section 23-64 (Basic Height and Setback Requirements).
(3) At least 55 percent of the total floor area permitted on the zoning lot shall be located in stories located either partially or entirely below a height of 150 feet.
When the lot coverage of the tower portion is less than 40 percent, the required 55 percent of the total floor area distribution, within a height of 150 feet, shall be increased in accordance with the following requirement:
Percent of Lot Coverage of the Tower Portion | Minimum Percent of Total Building Floor Area Distribution Below the Level of 150 Feet |
40.0 or greater | 55.0 |
39.0 to 39.9 | 55.5 |
38.0 to 38.9 | 56.0 |
37.0 to 37.9 | 56.5 |
36.0 to 36.9 | 57.0 |
35.0 to 35.9 | 57.5 |
34.0 to 34.9 | 58.0 |
33.0 to 33.9 | 58.5 |
32.0 to 32.9 | 59.0 |
31.0 to 31.9 | 59.5 |
30.0 to 30.9 | 60.0 |
(4) At all levels, such tower shall be set back from the street wall of a base at least 15 feet along a narrow street and at least 10 feet along a wide street, except that such dimensions shall include the depth of any permitted recesses in the street wall.
(5) No tower or portion thereof shall be located on a narrow street at a distance that is more than 100 feet from the intersection with a wide street.
Unenclosed balconies, subject to the provisions of Section 23-13 (Balconies), are permitted to project into or over open areas not occupied by towers.
For the purposes of determining the permitted tower coverage and the required minimum distance between buildings or portions thereof, that portion of a zoning lot located within 125 feet from the wide street frontage along the short dimension of a block shall be treated as if it were a separate zoning lot.
(b) Building base regulations
(1) Street wall location
(i) On a wide street, and on a narrow street within 125 feet of its intersection with a wide street, the street wall of the base shall occupy the entire street frontage of a zoning lot not occupied by existing buildings. At any height, at least 70 percent of the width of such street wall shall be located within eight feet of the street line, and the remaining 30 percent of such street wall may be recessed beyond eight feet of the street line to provide outer courts or balconies.
However, no such recesses shall be permitted within 20 feet of an adjacent building fronting on the same street line or within 30 feet of the intersection of two street lines.
However, no such recesses shall be permitted within 20 feet of an adjacent building fronting on the same street line or within 30 feet of the intersection of two street lines.
(ii) On a narrow street beyond 125 feet from its intersection with a wide street, no street wall of a base is required nor shall any street wall provided beyond 125 feet count toward the computation of any permitted recesses on such wall.
(iii) Where the street wall of an adjacent building fronting on the same street line is located within 10 feet of the street line, the street wall of the base shall be either located at the street line or aligned with the street wall of the adjacent building for a distance of not less than 20 feet measured horizontally from the side wall of such existing building.
(2) Height of street wall
All street walls of a base shall rise vertically without setback to a height of not less than 60 feet nor more than 85 feet except:
All street walls of a base shall rise vertically without setback to a height of not less than 60 feet nor more than 85 feet except:
(i) On a wide street, if the height of the street wall of an adjacent building fronting on the same street line exceeds 60 feet and if such street wall is located within 10 feet of the street line, the street wall of the base shall match the height of the street wall of the adjacent building to a maximum height of 100 feet by either of three alternatives:
(a) the street wall of the base shall be extended vertically to the height of the adjacent building for a distance of not less than 20 feet measured horizontally from the side wall of such adjacent building;
(b) at least 50 percent of the width of the street wall of the base shall be extended vertically to the height of the adjacent building; or
(c) a dormer shall be provided pursuant to paragraph (b)(3) of this Section. Such dormer shall match the height of the adjacent building.
Such street wall of the base fronting on a wide street may be extended along a narrow street within 70 feet of its intersection with the wide street.
(ii) On a narrow street beyond 100 feet of its intersection with a wide street, the street wall of a base shall rise vertically to a height of at least 60 feet when the adjacent building is either less than 60 feet or greater than 85 feet, or match the height of the adjacent building when the height of such building is between 60 feet and 85 feet.
For the purposes of this paragraph, (b)(2), inclusive, the height of an adjacent building shall be the height of a street wall, before setback, if applicable, of that portion of an existing building nearest the development or enlargement, fronting on the same street line, and located on the same or an adjoining zoning lot.
(3) Dormer
For the purposes of this Section, a dormer shall be a vertical extension of the street wall of a base allowed as a permitted obstruction within a required front setback area. A dormer may be located anywhere on a wide street, and on a narrow street within 70 feet of its intersection with a wide street.
On any street frontage, the aggregate width of all dormers at the required initial setback level shall not exceed 60 percent of the width of the street wall of the highest story of the base. For each foot of height above the base, the aggregate width of all dormers at that height shall be decreased by one percent of the street wall width of the highest story of the base. Such dormer shall count as floor area but not as tower lot coverage.
For the purposes of this Section, a dormer shall be a vertical extension of the street wall of a base allowed as a permitted obstruction within a required front setback area. A dormer may be located anywhere on a wide street, and on a narrow street within 70 feet of its intersection with a wide street.
On any street frontage, the aggregate width of all dormers at the required initial setback level shall not exceed 60 percent of the width of the street wall of the highest story of the base. For each foot of height above the base, the aggregate width of all dormers at that height shall be decreased by one percent of the street wall width of the highest story of the base. Such dormer shall count as floor area but not as tower lot coverage.
(4) Open areas
All open areas at ground level, located between the street line and the street wall of a base shall be landscaped except in front of entrances and exits to the building.
All open areas at ground level, located between the street line and the street wall of a base shall be landscaped except in front of entrances and exits to the building.
(c) Modification of tower coverage and floor area distribution requirements
The tower lot coverage and floor area distribution requirements set forth in paragraph (a)(3) of this Section shall be modified for buildings that provide articulation of a base in accordance with the following provisions:
The tower lot coverage and floor area distribution requirements set forth in paragraph (a)(3) of this Section shall be modified for buildings that provide articulation of a base in accordance with the following provisions:
(1) Recesses
Recesses shall occupy, in the aggregate, between 30 and 50 percent of the width of each eligible story of the base, and measure at least two feet in depth. In addition, the width of any individual recess provided within eight feet of the street line shall not exceed 25 percent of the width of the street wall of the base, unless such recess is provided in combination with an additional recess located beyond eight feet of the street line.
Furthermore, all recesses shall comply with the provisions of paragraph (b)(1) of this Section or paragraph (a)(1) of Section 35-64 (Special Tower Regulations for Mixed Buildings), as applicable. For each street frontage of a building with recesses provided in accordance with this paragraph, (c)(1), the percent of lot coverage of the tower portion of the building may be decreased by 0.5 percent, and the minimum percent of total building floor area distribution below a level of 150 feet may be reduced by 0.25 percent.
Recesses shall occupy, in the aggregate, between 30 and 50 percent of the width of each eligible story of the base, and measure at least two feet in depth. In addition, the width of any individual recess provided within eight feet of the street line shall not exceed 25 percent of the width of the street wall of the base, unless such recess is provided in combination with an additional recess located beyond eight feet of the street line.
Furthermore, all recesses shall comply with the provisions of paragraph (b)(1) of this Section or paragraph (a)(1) of Section 35-64 (Special Tower Regulations for Mixed Buildings), as applicable. For each street frontage of a building with recesses provided in accordance with this paragraph, (c)(1), the percent of lot coverage of the tower portion of the building may be decreased by 0.5 percent, and the minimum percent of total building floor area distribution below a level of 150 feet may be reduced by 0.25 percent.
(2) Dormers
For each street frontage with dormers, provided in accordance with paragraph (b)(3) of this Section, that measure, at their lowest level, at least 50 percent of the width of the street wall of the highest story of the base, and measure, at their highest level, at least 25 percent of the width of the highest story of the base, and rise at least 25 feet above the base, the percent of lot coverage of the tower portion of the building may be decreased by 0.5 percent, and the minimum percent of total building floor area distribution below a level of 150 feet may be reduced by 0.25 percent.
For each street frontage with dormers, provided in accordance with paragraph (b)(3) of this Section, that measure, at their lowest level, at least 50 percent of the width of the street wall of the highest story of the base, and measure, at their highest level, at least 25 percent of the width of the highest story of the base, and rise at least 25 feet above the base, the percent of lot coverage of the tower portion of the building may be decreased by 0.5 percent, and the minimum percent of total building floor area distribution below a level of 150 feet may be reduced by 0.25 percent.
(3) Matching provision
For each street frontage that provides an extension of the street wall of a base that matches the height of an adjacent building in accordance with paragraph (b)(2)(i)(b) of this Section, the percent of lot coverage of the tower portion of the building may be decreased by 0.5 percent, and the minimum percent of total building floor area distribution below a level of 150 feet may be reduced by 0.25 percent.
For each street frontage that provides an extension of the street wall of a base that matches the height of an adjacent building in accordance with paragraph (b)(2)(i)(b) of this Section, the percent of lot coverage of the tower portion of the building may be decreased by 0.5 percent, and the minimum percent of total building floor area distribution below a level of 150 feet may be reduced by 0.25 percent.
However, the total percent of lot coverage of the tower portion of the building shall not be decreased by more than 2.0 percent, nor shall the minimum percent of total building floor area distribution below a level of 150 feet be reduced by more than 1.0 percent.
Upcodes Diagrams
Related Code Sections
3108.2 Special Construction, Location and Access
Towers shall be located and equipped with step bolts and ladders so as to provide ready access for inspection purposes. Guy wires or other ...
3108.2 Special Construction, Location and Access
Towers shall be located and equipped with step bolts and ladders so as to provide ready access for inspection purposes. Guy wires or other ...
1613.1 Structural Design, Scope
other regulations provide seismic criteria, such as vehicular bridges, electrical transmission towers, hydraulic structures, buried utility lines ...
C101.1 Water Conservation Systems, General
of lavatories from public restrooms in commercial office buildings, and the treated effluent from an approved black water treatment system as regulated ...
1613.1 Structural Design, Scope
of their response characteristics and environment that are not addressed by this code or ASCE 7-10 and for which other regulations provide seismic criteria ...