808.3.1.2 Toplighting
JUMP TO FULL CODE CHAPTER
The daylit area shall be illuminated by a roof fenestration assembly such as a skylight, sloped glazing or tubular daylighting device that complies with Table 808.3.1.1 and Figure 808.3.1.2. The daylit area extends laterally and longitudinally beyond the glazed opening of the roof fenestration assembly to the nearest 56-inch-high (1422 mm) partition, or up to 0.7 times the height from the floor to the bottom of the rough opening of the daylighting well, whichever is less, as indicated in Figure 808.3.1.2.
For SI: 1 inch = 25.4 mm.
FIGURE 808.3.1.2
DAYLIT AREA UNDER A SKYLIGHT
Related Code Sections
808.3.1.2 Indoor Environmental Quality and Comfort, Toplighting
The daylit area shall be illuminated by a roof fenestration assembly such as a skylight, sloped glazing or tubular daylighting device that complies ...
Green Construction Code 2012 > 8 Indoor Environmental Quality and Comfort > 808 Daylighting > 808.3 Daylit Area of Building Spaces > 808.3.1 Daylight Prescriptive Requirements > 808.3.1.2 Toplighting
C405.2.3.3 [CE] Commercial Energy Efficiency, Toplight Daylight Zone
The toplight daylight zone is the floor area underneath a roof fenestration assembly which complies with all of the following: The daylight zone ...
Energy Conservation Code 2015 > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.3 Daylight-Responsive Controls > C405.2.3.3 Toplight Daylight Zone
808.3.1 Indoor Environmental Quality and Comfort, Daylight Prescriptive Requirements
Daylit areas shall comply with the following:
Each daylit area shall be located within a toplight or sidelight daylight zone, determined ...
Green Construction Code 2015 > 8 Indoor Environmental Quality and Comfort > 808 Daylighting > 808.3 Daylit Area of Building Spaces > 808.3.1 Daylight Prescriptive Requirements
608.5 Energy Conservation, Efficiency and Co2e Emission Reduction, Daylight Responsive Controls
watts of general lighting within toplight daylight zones. Exception: Daylight responsive controls are not required for the following: Spaces ...
Green Construction Code 2015 > 6 Energy Conservation, Efficiency and Co2e Emission Reduction > 608 Building Electrical Power and Lighting Systems > 608.5 Daylight Responsive Controls
608.5 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Automatic Daylight Controls
controls . Exception: Automatic daylight controls are not required for the following spaces and equipment: Toplighting daylit areas where ...
Green Construction Code 2012 > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 608 Building Electrical Power and Lighting Systems > 608.5 Automatic Daylight Controls