• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

C405.2.3.3 Toplight Daylight Zone

Energy Conservation Code 2015 of Colorado > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.3 Daylight-Responsive Controls > C405.2.3.3 Toplight Daylight Zone
JUMP TO FULL CODE CHAPTER

The toplight daylight zone is the floor area underneath a roof fenestration assembly which complies with all of the following:

  1. The daylight zone shall extend laterally and longitudinally beyond the edge of the roof fenestration assembly to the nearest obstruction that is taller than 0.7 times the ceiling height, or up to 0.7 times the ceiling height, whichever is less, as indicated in Figure C405.2.3.3.
  2. No building or geological formation blocks direct sunlight from hitting the roof fenestration assembly at the peak solar angle on the summer solstice.
  3. Where located in existing buildings, the product of the visible transmittance of the roof fenestration assembly and the area of the rough opening of the roof fenestration assembly divided by the area of the daylight zone is not less than 0.008.

FIGURE C405.2.3.3

DAYLIGHT ZONE UNDER A ROOF FENESTRATION ASSEMBLY

Related Code Sections


C405.2.3.3 [CE] Commercial Energy Efficiency, Toplight Daylight Zone
The toplight daylight zone is the floor area underneath a roof fenestration assembly which complies with all of the following: The daylight zone ...
Energy Conservation Code 2015 of Colorado > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.3 Daylight-Responsive Controls > C405.2.3.3 Toplight Daylight Zone
C402.4.4 [CE] Commercial Energy Efficiency, Daylight Zones
Daylight zones referenced in Sections C402.4.1.1 through C402.4.3.2 shall comply with Sections C405.2.3.2 and C405.2.3.3, as applicable. Daylight ...
Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C402 Building Envelope Requirements > C402.4 Fenestration (Prescriptive) > C402.4.4 Daylight Zones
C405.2.3 [CE] Commercial Energy Efficiency, Daylight-Responsive Controls
Daylight-responsive controls complying with Section C405.2.3.1 shall be provided to control the electric lights within daylight zones ...
Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.3 Daylight-Responsive Controls
C405.2.3.1 [CE] Commercial Energy Efficiency, Daylight-Responsive Control Function
or lower. Daylight responsive controls shall be configured to completely shut off all controlled lights. Lights in sidelit zones in accordance ...
Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.3 Daylight-Responsive Controls > C405.2.3.1 Daylight-Responsive Control Function
C405.2.3.3 [CE] Commercial Energy Efficiency, Toplit Zone
C405.2.3.3(1) TOPLIT ZONE FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ...
Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.3 Daylight-Responsive Controls > C405.2.3.3 Toplit Zone
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE