1127A.8.2 Toilet Tissue Dispensers
JUMP TO FULL CODE CHAPTER
Toilet tissue dispensers shall be located on the wall or partition closest to the water closet, 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor. The outlet of the dispenser shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. (See Figure 11A-9B.)
Related Code Sections
1127A.8.2 Housing Accessibility, Toilet Tissue Dispensers
Toilet tissue dispensers shall be located on the wall or partition closest to the water closet, 7 inches (180 mm) minimum and 9 inches (230 mm ...
Los Angeles Building Code > 11A Housing Accessibility > 1127A Common Use Facilities > 1127A.8 Toilet Room Fixtures and Accessories > 1127A.8.2 Toilet Tissue Dispensers
11B-604.9.6 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Dispensers
Toilet paper dispensers shall comply with Section 11B -309.4 and shall be 7 inches ( 178 mm) minimum and 9 inches ( 229 mm) maximum in front ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-604 Water Closets and Toilet Compartments > 11B-604.9 Water Closets and Toilet Compartments for Children's Use > 11B-604.9.6 Dispensers
408.15.5 Special Detailed Requirements Based on Use and Occupancy, Special Provisions
Inmate exercise clothing and toilet paper tissue shall be the only combustible materials permitted in small management yards ...
Los Angeles Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 408 Group I-3 > 408.15 Small Management Yards > 408.15.5 Special Provisions
Section 1209 Interior Environment, Toilet and Bathroom Requirements
Walls, floors and partitions in toilet and bathrooms shall comply with Sections 1209.2.1 through ...
Section 1210 Interior Environment, Toilet and Bathroom Requirements
Walls, floors and partitions in toilet and bathrooms shall comply with Sections ...