Section 2903 Toilet Room Requirements
Go To Full Code Chapter
[P] 2903.1 Water Closet Compartment
Each water closet utilized by the public or employees shall occupy a separate compartment with walls or partitions and a door enclosing the fixtures to ensure privacy.
Exceptions:
- Water closet compartments shall not be required in a single-occupant toilet room with a lockable door.
- Toilet rooms located in day care and child care facilities and containing two or more water closets shall be permitted to have one water closet without an enclosing compartment.
- This provision is not applicable to toilet areas located within Group I-3 housing areas.
[P] 2903.2 Urinal Partitions
Each urinal utilized by the public or employees shall occupy a separate area with walls or partitions to provide privacy. The walls or partitions shall begin at a height not more than 12 inches (305 mm) from and extend not less than 60 inches (1524 mm) above the finished floor surface. The walls or partitions shall extend from the wall surface at each side of the urinal a minimum of 18 inches (457 mm) or to a point not less than 6 inches (152 mm) beyond the outermost front lip of the urinal measured from the finished back wall surface, whichever is greater.
Exceptions:
- Urinal partitions shall not be required in a single occupant or family or assisted use toilet room with a lockable door.
- Toilet rooms located in day care and child care facilities and containing two or more urinals shall be permitted to have one urinal without partitions.
[P] 2903.3 Interior Finish
Interior finish surfaces of toilet rooms shall comply with Section 1210.
Upcodes Diagrams
Related Code Sections
Section 2903 Plumbing Systems, Toilet Room Requirements
to ensure privacy.
Exceptions:
Water closet compartments shall not be required in a single-occupant toilet room with a lockable door.
Toilet ...
Section 310 General Regulations, Washroom and Toilet Room Requirements
Washrooms and toilet rooms shall be illuminated and ventilated in accordance with the International Building Code and International Mechanical Code ...
Section 310 General Regulations, Washroom and Toilet Room Requirements
Washrooms and toilet rooms shall be illuminated and ventilated in accordance with the International Building Code and International Mechanical Code ...
Section 310 General Regulations, Washroom and Toilet Room Requirements
compartments shall not be required in a single-occupant toilet room with a lockable door.
Toilet rooms located in day care and child-care facilities ...
310.1 General Regulations, Light and Ventilation
Washrooms and toilet rooms shall be illuminated and ventilated in accordance with the International Building Code and International Mechanical Code ...