• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1227.12.10 Toilet and Bath Facilities

Los Angeles Building Code > 12 Interior Environment > 1227 [OSHPD 4] Correctional Treatment Centers > 1227.12 Nursing Service Space > 1227.12.10 Toilet and Bath Facilities
JUMP TO FULL CODE CHAPTER

Separate toilet room facilities shall be provided for the use of patients and personnel.

1227.12.10.1 Bathroom Facilities

Provide for patients in the nursing unit in at least the following ratios:

Bathtubs or showers1:12 patients
(Minimum one bathtub on each floor providing skilled nursing or intermediate care services)
Lavatories1:8 patients
(Fixtures shall be equipped without aerators and may have conventional controls. Gooseneck spouts shall not be used)
Toilets1:6 patients

Fixtures serving individual patient rooms shall not be considered as meeting the required ratios for bedrooms not served by individual adjoining toilet rooms or bathrooms.

Changes in these ratios for wards or units in which bed patients only are to be cared for may be permitted by the enforcing agency.

Related Code Sections


11B-223.1.1.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Toilet and Bathing Facilities
Toilet/bathing rooms which are part of patient bedrooms added or altered and required to be accessible shall comply with Section 11B -805.2.4 ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-223 Medical Care and Long-Term Care Facilities > 11B-223.1 General > 11B-223.1.1 Alterations > 11B-223.1.1.3 Toilet and Bathing Facilities
11B-806.2.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Toilet and Bathing Facilities
compartments shall comply with Section 11B -608.2.2 or 11B -608.2.3. Toilet and bathing fixtures required to comply with Sections 11B -603 through ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-806 Transient Lodging Guest Rooms > 11B-806.2 Guest Rooms With Mobility Features > 11B-806.2.4 Toilet and Bathing Facilities
11B-807.2.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Toilet and Bathing Facilities
Toilet facilities or bathing facilities that are provided as part of a cell shall comply with Section 11B -603. Where provided, no fewer than one ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-807 Holding Cells and Housing Cells > 11B-807.2 Cells With Mobility Features > 11B-807.2.4 Toilet and Bathing Facilities
1227.12.10 Interior Environment, Toilet and Bath Facilities
Separate toilet room facilities shall be provided for the use of patients and personnel ...
Los Angeles Building Code > 12 Interior Environment > 1227 [OSHPD 4] Correctional Treatment Centers > 1227.12 Nursing Service Space > 1227.12.10 Toilet and Bath Facilities
305.9.4 Provisions for All Compliance Methods, Toilet and Bathing Facilities
Where toilet rooms are provided, not fewer than one accessible family or assisted-use toilet room complying with Section 1109.2.1 ...
Los Angeles Existing Building Code > 3 Provisions for All Compliance Methods > 305 Accessibility for Existing Buildings (Not Adopted by HCD) > 305.9 Historic Buildings > 305.9.4 Toilet and Bathing Facilities
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE