604.8.1.4 Toe Clearance
JUMP TO FULL CODE CHAPTER
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side face of the partition, exclusive of partition support members. Compartments for children's use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor.
EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted water closet. Toe clearance at the side partition is not required in a compartment greater than 66 inches (1675 mm) wide. Toe clearance at the front partition is not required in a compartment for children's use that is greater than 65 inches (1650 mm) deep.
Related Code Sections
306.2 Building Blocks, Toe Clearance
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance ...
604.8.1.4 Plumbing Elements and Facilities, Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.8 Toilet Compartments > 604.8.1 Wheelchair Accessible Compartments > 604.8.1.4 Toe Clearance
305.4 Building Blocks, Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306 ...
2010 ADA Standards > 3 Building Blocks > 305 Clear Floor or Ground Space > 305.4 Knee and Toe Clearance
306.2.5 Building Blocks, Width
Toe clearance shall be 30 inches (760 mm) wide minimum. Figure 306.2 Toe Clearance ...
2010 ADA Standards > 3 Building Blocks > 306 Knee and Toe Clearance > 306.2 Toe Clearance > 306.2.5 Width
306.3 Building Blocks, Knee Clearance
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall ...