• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2107.2 TMS 402/ACI 530/ASCE 5, Section 8.1.6.7.1.1, Lap Splices

2017 FBC - Building, 6th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.2 TMS 402/ACI 530/ASCE 5, Section 8.1.6.7.1.1, Lap Splices
JUMP TO FULL CODE CHAPTER
As an alternative to Section 8.1.6.7.1.1, it shall be permitted to design lap splices in accordance with Section 2107.2.1.

2107.2.1 Lap Splices

The minimum length of lap splices for reinforcing bars in tension or compression, ld, shall be but not less than 12 inches (305 mm). In no case shall the length of the lapped splice be less than 40 bar diameters.

(Equation 21-1)
For SI:

where:

db = Diameter of reinforcement, inches (mm).

fs = Computed stress in reinforcement due to design loads, psi (MPa).

In regions of moment where the design tensile stresses in the reinforcement are greater than 80 percent of the allowable steel tension stress, Fs, the lap length of splices shall be increased not less than 50 percent of the minimum required length. Other equivalent means of stress transfer to accomplish the same 50 percent increase shall be permitted. Where epoxy coated bars are used, lap length shall be increased by 50 percent.

Related Code Sections


2107.2.1 Masonry, Lap Splices
The minimum length of lap splices for reinforcing bars in tension or compression, l d , shall be but not less than 12 inches (305 mm). In no case ...
2017 FBC - Building, 6th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.2 TMS 402/ACI 530/ASCE 5, Section 8.1.6.7.1.1, Lap Splices > 2107.2.1 Lap Splices
2107.2.1 Masonry, Lap Splices
The minimum length of lap splices for reinforcing bars in tension or compression, l d , shall be l d = 0.002 d b f s (Equation 21-1 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.2 TMS 402/ACI 530/ASCE 5, Section 2.1.7.7.1.1, Lap Splices. I > 2107.2.1 Lap Splices
2122.1 Masonry, Standards
unit masonry. In addition to TMS 402/ACI 530/ASCE 5 and TMS 602/ACI 530.1/ASCE 6, reinforced unit masonry structures shall comply with Sections 2122.2 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.1 Standards
Section 2108 Masonry, Strength Design of Masonry
of TMS 402/ACI 530/ASCE 5. Where plan review and inspections are performed by a local building department in accordance with Sections 107 and 110 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2108 Strength Design of Masonry
Section 2108 Masonry, Strength Design of Masonry
of TMS 402/ACI 530/ASCE 5, except as modified by Sections 2108.2 through 2108.4. Exceptions: AAC masonry shall comply with the requirements ...
2017 FBC - Building, 6th edition > 21 Masonry > 2108 Strength Design of Masonry
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE