• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2107.6 TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression

2017 FBC - Building, 6th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.6 TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
JUMP TO FULL CODE CHAPTER

Modify Section 6.1.5.1 as follows:

6.1.5.1 The required development length of reinforcing bars shall be determined by Equation (6-1), but shall not be less than 40 db and need not be greater than 72 db.


Equation 6-1 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors are changed as follows:

γ=1.0 for No. 3 (M#10) through No. 5 (M#16) bars;
γ=1.04 for No. 6 (M#19) through No. 7 (M#22) bars; and
γ=1.2 for No. 8 (M#25) through No. 11 (M#36) bars

Related Code Sections


2107.6 Masonry, TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
not be less than 40 db and need not be greater than 72 db. Equation 6-1 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors are changed as follows ...
2017 FBC - Building, 6th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.6 TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
2108.4 Masonry, TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
not be less than 40 db and need not be greater than 72 db. Equation 6-1 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors are changed as follows ...
2017 FBC - Building, 6th edition > 21 Masonry > 2108 Strength Design of Masonry > 2108.4 TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
Section 2108 Masonry, Strength Design of Masonry
of TMS 402/ACI 530/ASCE 5. Where plan review and inspections are performed by a local building department in accordance with Sections 107 and 110 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2108 Strength Design of Masonry
2107.5 Masonry, TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
), but shall not be less than 12 in. (305 mm), but need not be greater than 72 db. Equation 2-12 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors ...
2014 FBC - Building, 5th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.5 TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
2108.4 Masonry, TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
not be less than 12 in. (305 mm), but need not be greater than 72 db. Equation 2-12 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors ...
2014 FBC - Building, 5th edition > 21 Masonry > 2108 Strength Design of Masonry > 2108.4 TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE