2107.4 TMS 402/ACI 530/ASCE 5, Section 2.3.7, Maximum Bar Size
Go To Full Code Chapter
Add the following to Chapter 2:
2.3.7 Maximum bar size. The bar diameter shall not exceed one-eighth of the nominal wall thickness and shall not exceed one-quarter of the least dimension of the cell, course or collar joint in which it is placed.