• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2107.3 TMS 402/ACI 530/ASCE 5, Section 2.1.7.7, Splices of Reinforcement

2014 FBC - Building, 5th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.3 TMS 402/ACI 530/ASCE 5, Section 2.1.7.7, Splices of Reinforcement
JUMP TO FULL CODE CHAPTER

Modify Section 2.1.7.7 as follows:

2.1.7.7 Splices of reinforcement. Lap splices, welded splices or mechanical splices are permitted in accordance with the provisions of this section. All welding shall conform to AWS D1.4. Welded splices shall be of ASTM A 706 steel reinforcement. Reinforcement larger than No. 9 (M #29) shall be spliced using mechanical connections in accordance with Section 2.1.7.7.3.

Related Code Sections


2107.3 Masonry, TMS 402/ACI 530/ASCE 5, Section 2.1.7.7, Splices of Reinforcement
Modify Section 2.1.7.7 as follows: 2.1.7.7 Splices of reinforcement. Lap splices, welded splices or mechanical splices are permitted in accordance ...
2014 FBC - Building, 5th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.3 TMS 402/ACI 530/ASCE 5, Section 2.1.7.7, Splices of Reinforcement
2122.4 Masonry, Reinforcement
Reinforcement shall comply with TMS 402/ACI 530/ASCE 5 and TMS 602/ACI 530.1/ASCE 6 except as modified in Sections 2107 and 2108 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.4 Reinforcement
2122.4 Masonry, Reinforcement
Reinforcement shall comply with TMS 402/ACI 530/ASCE 5 and TMS 602/ACI 530.1/ASCE 6 except as modified herein Sections 2107 and 2108 ...
2017 FBC - Building, 6th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.4 Reinforcement
Section 2108 Masonry, Strength Design of Masonry
of TMS 402/ACI 530/ASCE 5. Where plan review and inspections are performed by a local building department in accordance with Sections 107 and 110 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2108 Strength Design of Masonry
Section 2108 Masonry, Strength Design of Masonry
of TMS 402/ACI 530/ASCE 5, except as modified by Sections 2108.2 through 2108.4. Exceptions: AAC masonry shall comply with the requirements ...
2017 FBC - Building, 6th edition > 21 Masonry > 2108 Strength Design of Masonry
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE