2108.4 TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
JUMP TO FULL CODE CHAPTER
Modify Section 2.1.7.3 as follows:
2.1.7.3 The required development length of reinforcing bars shall be determined by Equation (2- 12), but shall not be less than 12 in. (305 mm), but need not be greater than 72 db.
Equation 2-12 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors are changed as follows:
γ | = | 1.0 for No. 3 (M#10) through No. 5 (M#16) bars; |
γ | = | 1.04 for No. 6 (M#19) through No. 7 (M#22) bars; and |
γ | = | 1.2 for No. 8 (M#25) through No. 11 (M#36) bars. |
Related Code Sections
2107.5 Masonry, TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
), but shall not be less than 12 in. (305 mm), but need not be greater than 72 db. Equation 2-12 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors ...
2014 FBC - Building, 5th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.5 TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
2108.4 Masonry, TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
not be less than 12 in. (305 mm), but need not be greater than 72 db. Equation 2-12 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors ...
2014 FBC - Building, 5th edition > 21 Masonry > 2108 Strength Design of Masonry > 2108.4 TMS 402/ACI 530/ASCE 5, Section 2.1.7.3, Development of Bars in Tension and Compression
Section 2108 Masonry, Strength Design of Masonry
of TMS 402/ACI 530/ASCE 5, except as modified by Sections 2108.2 through 2108.4. Exceptions: AAC masonry shall comply with the requirements ...
2107.6 Masonry, TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
not be less than 40 db and need not be greater than 72 db. Equation 6-1 from TMS 402/ACI 530/ASCE 5, unchanged. Gamma factors are changed as follows ...
2017 FBC - Building, 6th edition > 21 Masonry > 2107 Allowable Stress Design > 2107.6 TMS 402/ACI 530/ASCE 5, Section 6.1.5.1 Development of Bar Reinforcement in Tension or Compression
Section 2107 Masonry, Allowable Stress Design
building department in accordance with Sections 107 and 110, the provisions of TMS 402/ACI 530/ASCE 5, Chapter 3 Section 3.1 and TMS 602/ACI 530.1/ASCE 6 ...