1810.3.2.4 Timber
JUMP TO FULL CODE CHAPTER
Timber deep foundation elements shall be designed as piles or poles in accordance with ANSI/AWC NDS. Round timber elements shall conform to ASTM D25. Sawn timber elements shall conform to DOC PS-20.
Timber deep foundation elements used to support permanent structures shall be treated in accordance with this section unless it is established that the tops of the untreated timber elements will be below the lowest ground-water level assumed to exist during the life of the structure. Preservative and minimum final retention shall be in accordance with AWPA U1 (Commodity Specification E, Use Category 4C) for round timber elements and AWPA U1 (Commodity Specification A, Use Category 4B) for sawn timber elements. Preservative-treated timber elements shall be subject to a quality control program administered by an approved agency. Element cutoffs shall be treated in accordance with AWPA M4.
Related Code Sections
1810.3.2.4 Soils and Foundations, Timber
Timber deep foundation elements shall be designed as piles or poles in accordance with ANSI/AWC NDS. Round timber elements shall conform to ASTM D25 ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.3 Design and Detailing > 1810.3.2 Materials > 1810.3.2.4 Timber
1810.3.2.4 Soils and Foundations, Timber
Timber deep foundation elements shall be designed as piles or poles in accordance with ANSI/AWC NDS. Round timber elements shall conform to ASTM D25 ...
2020 Building Code of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.3 Design and Detailing > 1810.3.2 Materials > 1810.3.2.4 Timber
1805.4.5 Soils and Foundations, Timber Footings
Timber footings are permitted for buildings of Type V construction and as otherwise approved by the code enforcement official. Such footings shall ...
2010 Building Code of NY > 18 Soils and Foundations > 1805 Footings and Foundations > 1805.4 Footings > 1805.4.5 Timber Footings
1809.1 Soils and Foundations, Timber Piles
Timber piles shall be designed in accordance with the AFPA NDS ...
2010 Building Code of NY > 18 Soils and Foundations > 1809 Driven Pile Foundations > 1809.1 Timber Piles
1809.12 Soils and Foundations, Timber Footings
Timber footings shall be permitted for buildings of Type V construction and as otherwise approved by the building official . Such footings shall ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1809 Shallow Foundations > 1809.12 Timber Footings