E4206.8 Through-Wall Lighting Assembly
JUMP TO FULL CODE CHAPTER
A through-wall lighting assembly shall be equipped with a threaded entry or hub, or a nonmetallic hub, for the purpose of accommodating the termination of the supply conduit. A through-wall lighting assembly shall meet the construction requirements of Section E4205.4 and be installed in accordance with the requirements of Section E4206.5 Where connection to a forming shell is specified, the connection shall be to the conduit termination point. [680.23(E)]
Related Code Sections
E4206.8 Swimming Pools [Electrical Provisions], Through-Wall Lighting Assembly
A through-wall lighting assembly shall be equipped with a threaded entry or hub, or a nonmetallic hub, for the purpose of accommodating ...
2014 FBC - Residential, 5th edition > 42 Swimming Pools [Electrical Provisions] > E4206 Equipment Installation > E4206.8 Through-Wall Lighting Assembly
E4206.8 Swimming Pools [Electrical Provisions], Through-Wall Lighting Assembly
A through-wall lighting assembly shall be equipped with a threaded entry or hub, or a nonmetallic hub, for the purpose of accommodating ...
2017 FBC - Residential, 6th edition > 42 Swimming Pools [Electrical Provisions] > E4206 Equipment Installation > E4206.8 Through-Wall Lighting Assembly
E4205.1 Swimming Pools [Electrical Provisions], Equipment to Be Grounded
The following equipment shall be grounded: Through-wall lighting assemblies and underwater luminaires other than those low-voltage lighting ...
2014 FBC - Residential, 5th edition > 42 Swimming Pools [Electrical Provisions] > E4205 Grounding > E4205.1 Equipment to Be Grounded
E4205.1 Swimming Pools [Electrical Provisions], Equipment to Be Grounded
The following equipment shall be grounded: Through-wall lighting assemblies and underwater luminaires other than those low-voltage lighting ...
2017 FBC - Residential, 6th edition > 42 Swimming Pools [Electrical Provisions] > E4205 Grounding > E4205.1 Equipment to Be Grounded
E4201.2 Swimming Pools [Electrical Provisions], Definitions
fabric walls regardless of dimension. THROUGH-WALL LIGHTING ASSEMBLY. A lighting assembly intended for installation above grade, on or through ...
2014 FBC - Residential, 5th edition > 42 Swimming Pools [Electrical Provisions] > E4201 General > E4201.2 Definitions