1126A.2.1 Thresholds and Changes in Elevation
JUMP TO FULL CODE CHAPTER
The floor or landing shall not be more than 1/2 inch (12.7 mm) lower than the top of the threshold of the doorway. (See Figure 11A-8I.)
Changes in level between 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope). Changes in level greater than 1/2 inch (12.7 mm) shall be accomplished by means of a ramp. (See Section 1122A.)
Related Code Sections
1126A.2.1 Housing Accessibility, Thresholds and Changes in Elevation
The floor or landing shall not be more than 1 / 2 inch (12.7 mm) lower than the top of the threshold of the doorway. (See Figure 11A-8I.) Changes ...
Los Angeles Building Code > 11A Housing Accessibility > 1126A Doors, Gates and Windows > 1126A.2 Level Floor or Landing > 1126A.2.1 Thresholds and Changes in Elevation
1119A.5 Housing Accessibility, Changes in Elevation
Interior accessible routes which have changes in elevation shall be transitioned and comply with Sections 1121A or 1122A. Exception: Doors ...
Los Angeles Building Code > 11A Housing Accessibility > 1119A Interior Accessible Routes > 1119A.5 Changes in Elevation
1010.1.7 Means of Egress, Thresholds
units, where Exception 5 to Section 1010.1.5 permits a 4-inch (102 mm) elevation change at the door, the threshold height on the exterior side ...
Los Angeles Building Code > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.7 Thresholds
1010.1.7 Means of Egress, Thresholds
or 1 / 2 inch (12.7 mm) above the finished floor or landing for other doors. Raised thresholds and floor level changes greater than 1 / 4 inch ...
2017 LA City Fire Code > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.7 Thresholds
1132A.4.1 Housing Accessibility, Thresholds
, including sliding door tracks, shall be no higher than 3 / 4 inch (19.05 mm). Changes in height at interior door thresholds (e.g., floor material changes ...
Los Angeles Building Code > 11A Housing Accessibility > 1132A Doors > 1132A.4 Level Floor or Landing > 1132A.4.1 Thresholds