For sunroom additions not exceeding 500 square feet (46 m2) in area, the minimum ceiling insulation R-values shall be R-19 in Zone 4 and R-24 in Zones 5 and 6. The minimum wall R-value shall be R-13 in all zones. New wall(s), windows and doors separating such sunroom addition from conditioned space shall meet the building thermal envelope requirements of Table 402.1.1.