Roofing materials shall have a CRRC initial or aged thermal emittance as determined in accordance with ASTM E408 or C1371 equal to or greater than those specified in Table A5.106.11.2.2 for Tier 1 and Table A5.106.11.2.3 for Tier 2.
Thermal emittance may also be certified by other supervisory entities approved by the Energy Commission pursuant to Title 24, Part 1, California Administrative Code.
[BSC] TIER 1
ROOF SLOPECLIMATE ZONEMINIMUM AGED SOLAR REFLECTANCETHERMAL EMITTANCESRI
≤ 2:121—160.630.7575
> 2:121—160.200.7516