• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.305(a)(2)(iv) The Following Requirements Apply to Feeders:

OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(a) Wiring Methods > 1910.305(a)(2) Temporary Wiring > 1910.305(a)(2)(iv) The Following Requirements Apply to Feeders:
JUMP TO FULL CODE CHAPTER

1910.305(a)(2)(iv)(A)

Feeders shall originate in an approved distribution center.

1910.305(a)(2)(iv)(B)

Conductors shall be run as multiconductor cord or cable assemblies. However, if installed as permitted in paragraph (a)(2)(i)(C) of this section, and if accessible only to qualified persons, feeders may be run as single insulated conductors.

Related Code Sections


1910.305(a)(2)(iv) Electrical, The Following Requirements Apply to Feeders:
Feeders shall originate in an approved distribution center ...
OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(a) Wiring Methods > 1910.305(a)(2) Temporary Wiring > 1910.305(a)(2)(iv) The Following Requirements Apply to Feeders:
1910.304(f)(2)(iv) Electrical, The Following Additional Requirements Apply to Feeders Only:
The continuous ampere rating of a fuse may not exceed three times the ampacity of the conductors. The long-time trip element setting of a breaker ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(f) Overcurrent Protection > 1910.304(f)(2) Feeders and Branch Circuits Over 600 Volts, Nominal > 1910.304(f)(2)(iv) The Following Additional Requirements Apply to Feeders Only:
1910.304(f) Electrical, Overcurrent Protection
The following requirements apply to overcurrent protection of circuits rated 600 volts, nominal, or less ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(f) Overcurrent Protection
1910.304(c) Electrical, Outside Conductors, 600 Volts, Nominal, or Less
The following requirements apply to branch-circuit, feeder, and service conductors rated 600 volts, nominal, or less and run outdoors as open ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(c) Outside Conductors, 600 Volts, Nominal, or Less
1910.304 Electrical, Wiring Design and Protection
The following requirements apply to branch-circuit, feeder, and service ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING