• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

105.3 Testing of Systems

Uniform Mechanical Code 2018 of Nevada > 1 Administration > 105.0 Inspections and Testing > 105.3 Testing of Systems
JUMP TO FULL CODE CHAPTER
Mechanical systems shall be tested and approved in accordance with this code or the Authority Having Jurisdiction. Tests shall be conducted in the presence of the Authority Having Jurisdiction or the Authority Having Jurisdiction's duly appointed representative.
No test or inspection shall be required where a mechanical system, or part thereof, is set up for exhibition purposes and has no connection with water or an energy fuel supply. In cases where it would be impractical to provide the required water or air tests, or for minor installations and repairs, the Authority Having Jurisdiction shall be permitted to make such inspection as deemed advisable in order to be assured that the work has been performed in accordance with the intent of this code. Joints and connections in the mechanical system shall be airtight, gastight, or watertight for the pressures required by the test.

105.3.1 Defective Systems

In buildings or premises condemned by the Authority Having Jurisdiction because of an insanitary condition of the mechanical system, or part thereof, the alterations in such system shall be in accordance with the requirements of this code.

105.3.2 Retesting

Where the Authority Having Jurisdiction finds that the work will not pass the test, necessary corrections shall be made, and the work shall be resubmitted for test or inspection.

105.3.3 Approval

Where prescribed tests and inspections indicate that the work is in accordance with this code, a certificate of approval shall be issued by the Authority Having Jurisdiction to the permittee on demand.

Related Code Sections


105.3 Administration, Testing of Systems
Mechanical systems shall be tested and approved in accordance with this code or the Authority Having Jurisdiction. Tests shall be conducted ...
Uniform Mechanical Code 2018 of Nevada > 1 Administration > 105.0 Inspections and Testing > 105.3 Testing of Systems
105.3 Administration, Testing of Systems
Plumbing systems shall be tested and approved in accordance with this code or the Authority Having Jurisdiction. Tests shall be conducted ...
Uniform Plumbing Code 2018 of Nevada > 1 Administration > 105.0 Inspections and Testing > 105.3 Testing of Systems
105.3.3 Administration, Approval
Where prescribed tests and inspections indicate that the work is in accordance with this code, a certificate of approval shall be issued ...
Uniform Plumbing Code 2018 of Nevada > 1 Administration > 105.0 Inspections and Testing > 105.3 Testing of Systems > 105.3.3 Approval
P2503.5.1 Plumbing Administration, Rough Plumbing
DWV systems shall be tested on completion of the rough piping installation by water or for piping systems other than plastic, by air with no evidence ...
Residential Code 2012 of Nevada > 25 Plumbing Administration > P2503 Inspection and Tests > P2503.5 DWV Systems Testing > P2503.5.1 Rough Plumbing
P2503.5.2 Plumbing Administration, Finished Plumbing
by visual inspection. Gas tightness. When required by the local administrative authority, a final test for gas tightness of the DWV system shall be made ...
Residential Code 2012 of Nevada > 25 Plumbing Administration > P2503 Inspection and Tests > P2503.5 DWV Systems Testing > P2503.5.2 Finished Plumbing
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING