Before an employee enters an enclosed space, the internal atmosphere shall be tested for flammable gases and vapors with a direct-reading meter or similar instrument capable of collection and immediate analysis of data samples without the need for off-site evaluation. This test shall be performed after the oxygen testing and ventilation required by paragraph (e)(9) of this section demonstrate that there is sufficient oxygen to ensure the accuracy of the test for flammability.

Related Code Sections

1910.146(c)(5)(ii)(C) General Environmental Controls,
, for flammable gases and vapors, and for potential toxic air contaminants, in that order. Any employee who enters the space, or that employee's authorized ...
1910.272(g)(1)(iii) Special Industries,
The atmosphere within a bin, silo, or tank shall be tested for the presence of combustible gases, vapors, and toxic agents when the employer has ...
1910.422(g)(5) Commercial Diving Operations,
Prior to welding or burning on closed compartments, structures or pipes, which contain a flammable vapor or in which a flammable vapor may ...
1910.146(d)(5)(iii) General Environmental Controls,
When testing for atmospheric hazards, test first for oxygen, then for combustible gases and vapors, and then for toxic gases and vapors ...