R609.3 Testing and Labeling
Go To Full Code Chapter
Exterior windows and sliding doors shall be tested by an approved independent laboratory, and bear a label identifying manufacturer, performance characteristics and approved inspection agency to indicate compliance with AAMA/WDMA/CSA 101/I.S.2/A440. Exterior side-hinged doors shall be tested and labeled as conforming to AAMA/WDMA/CSA 101/I.S.2/A440 or AMD 100, or comply with Section R609.5.
Exception: Decorative glazed openings.
R609.3.1 Comparative Analysis
Structural wind load design pressures for window and door units different than the size tested in accordance with Section R609.3 shall be permitted to be different than the design value of the tested unit where determined in accordance with one of the following comparative analysis methods:
- Structural wind load design pressures for window and door units smaller than the size tested in accordance with Section R609.3 shall be permitted to be higher than the design value of the tested unit provided such higher pressures are determined by accepted engineering analysis. Components of the smaller unit shall be the same as those of the tested unit. Where such calculated design pressures are used, they shall be validated by an additional test of the window or door unit having the highest allowable design pressure.
- In accordance with WDMA I.S.11.
Upcodes Diagrams
Related Code Sections
R308.6.9 Building Planning, Testing and Labeling
Unit skylights and tubular daylighting devices shall be tested by an approved independent laboratory, and bear a label identifying manufacturer ...
R609.3 Wall Construction, Testing and Labeling
Exterior windows and sliding doors shall be tested by an approved independent laboratory, and bear a label identifying manufacturer, performance ...
1703.5.1 Special Inspections and Tests, Testing
An approved agency shall test a representative sample of the product, material or assembly being labeled to the relevant standard or standards. The ...
1703.5.1 Special Inspections and Tests, Testing
An approved agency shall test a representative sample of the product, material or assembly being labeled to the relevant standard or standards. The ...
1703.5.1 Special Inspections and Tests, Testing
An approved agency shall test a representative sample of the product, material or assembly being labeled to the relevant standard or standards. The ...