UpCodes logo
// CODE SNIPPET

Section 2213A Testing and Field Verification

Jump To Full Code Chapter
2213A.1 Tests of High-Strength Bolts, Nuts and Washers
High-strength bolts, nuts and washers shall be sampled and tested by an approved independent testing laboratory for conformance with the requirements of applicable ASTM standards.
[OSHPD 1 and 4] A minimum of three samples per lot, as defined in the ASTM standards for bolts [and not nuts and washers], shall be tested for tensile properties in accordance with ASTM F606, but need not exceed three samples per 400 bolts.
2213A.2 Tests of End-Welded Studs
End-welded studs shall be tested in accordance with the requirements of the AWS D1.1, Sections 7.7 and 7.8.

Related Code Sections

Section 2213A Steel, Testing and Field Verification
High-strength bolts, nuts and washers shall be sampled and tested by an approved independent testing laboratory for conformance with the requirements ...
Section 2213A Steel, Testing and Field Verification
High-strength bolts, nuts and washers shall be sampled and tested in accordance with Section 1705A.2.6 [OSHPD 1 & 4] and this section. [OSHPD 1 ...
Section 2213A Steel, Testing and Field Verification
High-strength bolts, nuts and washers shall be sampled and tested by an approved agency for conformance with the requirements of applicable ASTM ...
2213A.2 Steel, Tests of End-Welded Studs
End-welded studs shall be tested in accordance with the requirements of the AWS D1.1, Sections 7.7 and 7.8 ...
2213A.1 Steel, Tests of High-Strength Bolts, Nuts and Washers
High-strength bolts, nuts and washers shall be sampled and tested by an approved agency for conformance with the requirements of applicable ASTM ...