In addition to the requirements set forth in subparts D and E of this part (29 CFR 1926.50 - 1926.107) to prevent exposure to harmful levels of atmospheric contaminants and to assure acceptable atmospheric conditions, the following requirements shall apply:
1926.651(g)(1)(i)
Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.
1926.651(g)(1)(iii)
Adequate precaution shall be taken such as providing ventilation, to prevent employee exposure to an atmosphere containing a concentration of a flammable gas in excess of 20 percent of the lower flammable limit of the gas.
1926.651(g)(1)(iv)
When controls are used that are intended to reduce the level of atmospheric contaminants to acceptable levels, testing shall be conducted as often as necessary to ensure that the atmosphere remains safe.
1926.651(g)(1)(ii)
Adequate precautions shall be taken to prevent employee exposure to atmospheres containing less than 19.5 percent oxygen and other hazardous atmospheres. These precautions include providing proper respiratory protection or ventilation in accordance with subparts D and E of this part respectively.

Related Code Sections

1926.651(g)(1) Excavations, Testing and Controls
substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth ...
1926.963(e)(2) Electric Power Transmission and Distribution, Instruments
The employer shall isolate meters and other instruments with accessible terminals or parts from test personnel to protect against hazards that could ...
1926.963(c)(1) Electric Power Transmission and Distribution, Safeguarding
The employer shall provide safeguarding within test areas to control access to test equipment or to apparatus under test that could become energized ...