1910.268(n)(5)(i)
Before attaching a splicing platform to a cable suspension strand, the strand shall be tested and determined to have strength sufficient to support the weight of the platform and the employee. Where the strand crosses above power wires or railroad tracks it may not be tested but shall be inspected in accordance with paragraph (n)(6) of this section.
1910.268(n)(5)(ii)
The following method or an equivalent method shall be used for testing the strength of the strand: A rope, at least three-eighths inch in diameter, shall be thrown over the strand. On joint lines, the rope shall be passed over the strand using tree pruner handles or a wire raising tool. If two employees are present, both shall grip the double rope and slowly transfer their entire weight to the rope and attempt to raise themselves off the ground. If only one employee is present, one end of the rope which has been passed over the strand shall be tied to the bumper of the truck, or other equally secure anchorage. The employee then shall grasp the other end of the rope and attempt to raise himself off the ground.

Related Code Sections

1910.268(n)(5) Special Industries, Test Requirements for Cable Suspension Strand
Before attaching a splicing platform to a cable suspension strand, the strand shall be tested and determined to have strength sufficient to support ...
1910.268(n)(1)(i) Special Industries,
The employer shall insure that when handling cable suspension strand which is being installed on poles carrying exposed energized power conductors ...
1910.268(s)(8) Special Industries, Cable
A conductor with insulation, or a stranded conductor with or without insulation and other coverings (single-conductor cable), or a combination ...