1402.2.1.2 Test Procedure, Sandy Soils
JUMP TO FULL CODE CHAPTER
The hole shall be filled with clear water to a minimum of 12 inches (305 mm) above the bottom of the hole for tests in sandy soils. The time for this amount of water to seep away shall be determined, and this procedure shall be repeated if the water from the second filling of the hole seeps away in 10 minutes or less. The test shall proceed as follows: Water shall be added to a point not more than 6 inches (152 mm) above the gravel or coarse sand. Thereupon, from a fixed reference point, water levels shall be measured at 10-minute intervals for a period of 1 hour. Where 6 inches (152 mm) of water seeps away in less than 10 minutes, a shorter interval between measurements shall be used, but in no case shall the water depth exceed 6 inches (152 mm). Where 6 inches (152 mm) of water seeps away in less than 2 minutes, the test shall be stopped and a rate of less than 3 minutes per inch (7.2 s/mm) shall be reported. The final water level drop shall be used to calculate the percolation rate. Soils not meeting the above requirements shall be tested in accordance with Section 1303.7.1.3.
Related Code Sections
1402.2.1.2 Subsurface Landscape Irrigation Systems, Test Procedure, Sandy Soils
The hole shall be filled with clear water to a minimum of 12 inches (305 mm) above the bottom of the hole for tests in sandy soils. The time ...
Plumbing Code 2015 of Alabama > 14 Subsurface Landscape Irrigation Systems > 1402 System Design and Sizing > 1402.2 Percolation Tests > 1402.2.1 Percolation Tests and Procedures > 1402.2.1.2 Test Procedure, Sandy Soils
P3009.8.1.2 Sanitary Drainage, Test Procedure, Sandy Soils
The hole shall be filled with clear water to not less than 12 inches (305 mm) above the bottom of the hole for tests in sandy soils. The time ...
Residential Code 2015 of Alabama > 30 Sanitary Drainage > P3009 Subsurface Landscape Irrigation Systems > P3009.8 Percolation Tests > P3009.8.1 Percolation Tests and Procedures > P3009.8.1.2 Test Procedure, Sandy Soils
R401.4 Foundations, Soil Tests
and sandy siltclay (CL, ML, MH and CH)
1,500 b
For SI: 1 pound per square foot = 0.0479 kPa.
Where soil tests are required by Section ...
1705.6 Special Inspections and Tests, Soils
Special inspections and tests of existing site soil conditions, fill placement and load-bearing requirements shall be performed in accordance ...
Building Code 2015 of Alabama > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.6 Soils
1704.7 Structural Tests and Special Inspections, Soils
Special inspections for existing site soil conditions, fill placement and load-bearing requirements shall be as required by this section and Table ...
Building Code 2009 of Alabama > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.7 Soils