In areas where hazard of termite damage is very heavy in accordance with Figure R301.2(6), foam plastic insulation shall be permitted below grade on foundation walls in accordance with one of the following conditions:
  1. When in addition to the requirements in Section R320.1, an approved method of protecting the foam plastic and structure from subterranean termite damage is provided.
  2. The structural members of walls, floors, ceilings and roofs are entirely of noncombustible materials or pressure preservatively treated wood.
  3. On the interior side of basement walls.

Related Code Sections

R404.4.7.2 Foundations, Termite Hazards
In areas where hazard of termite damage is very heavy in accordance with Figure R301.2(6), foam plastic insulation shall be permitted below grade ...
2304.11.6 Wood, Termite Protection
In geographical areas where hazard of termite damage is known to be very heavy, wood floor framing shall be of naturally durable species (termite ...
2304.12.4 Wood, Termite Protection
In geographical areas where hazard of termite damage is known to be very heavy, wood floor framing in the locations specified in Section 2304.12.1.1 ...
2304.12.4 Wood, Termite Protection
In geographical areas where hazard of termite damage is known to be very heavy, wood floor framing in the locations specified in Section 2304.12.2.1 ...
R314.7 Building Planning, Termite Damage
The use of foam plastics in areas of "very heavy" termite infestation probability shall be in accordance with Section R320.5 ...