1910.213(k)(1)
Feed chains and sprockets of all double end tenoning machines shall be completely enclosed, except for that portion of chain used for conveying the stock.
1910.213(k)(2)
At the rear ends of frames over which feed conveyors run, sprockets and chains shall be guarded at the sides by plates projecting beyond the periphery of sprockets and the ends of lugs.
1910.213(k)(3)
Each tenoning machine shall have all cutting heads, and saws if used, covered by metal guards. These guards shall cover at least the unused part of the periphery of the cutting head. If such a guard is constructed of sheet metal, the material used shall be not less than one-sixteenth inch in thickness, and if cast iron is used, it shall be not less than three-sixteenths inch in thickness.
1910.213(k)(4)
Where an exhaust system is used, the guard shall form part or all of the exhaust hood and shall be constructed of metal of a thickness not less than that specified in subparagraph (3) of this paragraph.

Related Code Sections

1910.213(k) Machinery and Machine Guarding, Tenoning Machines
Feed chains and sprockets of all double end tenoning machines shall be completely enclosed, except for that portion of chain used for conveying ...
1910.266(f) Special Industries, Machines
employer shall assure that each machine, including any machine provided by an employee ...
1910.212(a) Machinery and Machine Guarding, Machine Guarding
One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those ...
1910.213(p) Machinery and Machine Guarding, Sanding Machines
Feed rolls of self-feed sanding machines shall be protected with a semicylindrical guard to prevent the hands of the operator from coming in contact ...