Section 3308 Temporary Use of Streets, Alleys and Public Property
JUMP TO FULL CODE CHAPTER
Construction materials and equipment shall not be placed or stored so as to obstruct access to fire hydrants, standpipes, fire or police alarm boxes, catch basins or manholes, nor shall such material or equipment be located within 20 feet (6096 mm) of a street intersection, or placed so as to obstruct normal observations of traffic signals or to hinder the use of public transit loading platforms.
Building materials, fences, sheds or any obstruction of any kind shall not be placed so as to obstruct free approach to any fire hydrant, fire department connection, utility pole, manhole, fire alarm box or catch basin, or so as to interfere with the passage of water in the gutter. Protection against damage shall be provided to such utility fixtures during the progress of the work, but sight of them shall not be obstructed.
Related Code Sections
Section 1503 Construction Safeguards, Temporary Use of Streets, Alleys and Public Property
The temporary use of streets or public property for the storage or handling of materials or equipment required for construction or demolition ...
Existing Building Code 2018 of Illinois > 15 Construction Safeguards > 1503 Temporary Use of Streets, Alleys and Public Property
Section 1503 Construction Safeguards, Temporary Use of Streets, Alleys and Public Property
The temporary use of streets or public property for the storage or handling of materials or equipment required for construction or demolition ...
Existing Building Code 2021 of Illinois > 15 Construction Safeguards > 1503 Temporary Use of Streets, Alleys and Public Property
Section 3308 Safeguards During Construction, Temporary Use of Streets, Alleys and Public Property
The temporary use of streets or public property for the storage or handling of materials or of equipment required for construction or demolition ...
Building Code 2021 of Illinois > 33 Safeguards During Construction > 3308 Temporary Use of Streets, Alleys and Public Property
Section 3308 Safeguards During Construction, Temporary Use of Streets, Alleys and Public Property
The temporary use of streets or public property for the storage or handling of materials or of equipment required for construction or demolition ...
Building Code 2018 of Illinois > 33 Safeguards During Construction > 3308 Temporary Use of Streets, Alleys and Public Property
1503.3 Construction Safeguards, Utility Fixtures
Building materials, fences, sheds or any obstruction of any kind shall not be placed so as to obstruct free approach to any fire hydrant, fire ...
Existing Building Code 2021 of Illinois > 15 Construction Safeguards > 1503 Temporary Use of Streets, Alleys and Public Property > 1503.3 Utility Fixtures