A temporary staging cell or room shall:
  1. Be constructed for the purpose of holding inmates who have been classified and segregated in accordance with Sections 1050 and 1053 of Title 15, Division 1, California Code of Regulations.
  2. Be limited to holding inmates up to four hours.
  3. Be limited to no more than 80 inmates.
  4. Contain a minimum of 10 square feet (0.93 m2) of floor area per inmate and a clear ceiling height of 8 feet (2438 mm) or more.
  5. Be no smaller than 160 square feet (14.9 m2).
  6. Contain seating to accommodate all inmates as required in Section 1231.3.
  7. Contain toilet, wash basin and drinking fountain as specified in Section 1231.3.
  8. Maximize visual supervision of inmates by staff.

Related Code Sections

1231.2.3 Interior Environment, Temporary Staging Cell or Room
A temporary staging cell or room shall: Be constructed for the purpose of holding inmates who have been classified and segregated in accordance ...
1231.2.3 Interior Environment, Temporary Staging Cell or Room
A temporary staging cell or room shall: Be constructed for the purpose of holding inmates who have been classified and segregated in accordance ...
1231.2.3 Interior Environment, Temporary Staging Cell or Room
A temporary staging cell or room shall: Be constructed for the purpose of holding inmates who have been classified and segregated in accordance ...
1231.2.22 Interior Environment, Audio Monitoring System
in temporary holding cells or rooms, temporary staging cells or rooms, sobering cells, safety cells, single and double occupancy cells, dormitories ...
1231.3.3 Interior Environment, Drinking Fountains
staging cell, sobering cell, and be accessible to the occupants of day rooms and exercise areas. Additional drinking fountains shall be located ...