Section 117 Temporary and Moved Buildingsand Structures; Demolition

Jump To Full Code Chapter
117.1 Temporary Buildings and Structures
The building official is authorized to issue a permit for temporary buildings or structures. Such permits shall be limited as to time of service, but shall not be permitted for more than one year, except that upon the permit holder's written request, the building official may grant one or more extensions of time, not to exceed one year per extension. The building official is authorized to terminate the approval and order the demolition or removal of temporary buildings or structures during the period authorized by the permit when determined necessary.
117.1.1 Temporary Uses Within Existing Buildings and Structures
The building official shall review and may approve conditions or modifications for temporary uses, including hypothermia and hyperthermia shelters, that may be necessary as long as the use meets the spirit and functional intent intended by this code. The building official is authorized to terminate the approval and order the discontinuance of the temporary use during the period authorized by the permit when determined necessary. The building official shall notify the appropriate fire official or fire chief of the approved temporary use.
117.2 Moved Buildings and Structures
Any building or structure moved into a locality or moved to a new location within a locality shall not be occupied or used until a certification of occupancy is issued for the new location. Such moved buildings or structures shall be required to comply with the requirements of this code for a newly constructed building or structure unless meeting all of the following requirements relative to the new location:
  1. There is no change in the occupancy classification from its previous location.
  2. The building or structure was in compliance with all state and local requirements applicable to it in its previous location and is in compliance with all state and local requirements applicable if originally constructed in the new location.
  3. The building or structure did not become unsafe during the moving process due to structural damage or for other reasons.
  4. Any alterations, reconstruction, renovations or repairs made pursuant to the move are in compliance with applicable requirements of the VRC.
117.3 Demolition of Buildings and Structures
Prior to the issuance of a permit for the demolition of any building or structure, the owner or the owner's agent shall provide certification to the building official that all service connections of utilities have been removed, sealed or plugged satisfactorily and a release has been obtained from the associated utility company. The certification shall further provide that written notice has been given to the owners of adjoining lots and any other lots that may be affected by the temporary removal of utility wires or the temporary disconnection or termination of other services or facilities relative to the demolition. In addition, the requirements of Chapter 33 of the International Building Code for any necessary retaining walls or fences during demolition shall be applicable and when a building or structure is demolished or removed, the established grades shall be restored.

Related Code Sections

Section 117 Administration, Temporary and Moved Buildingsand Structures; Demolition
The building official is authorized to issue a permit for temporary buildings or structures. Such permits shall be limited as to time of service ...
Section 117 Administration, Temporary and Moved Buildingsand Structures; Demolition
The building official is authorized to issue a permit for temporary buildings or structures. Such permits shall be limited as to time of service ...
117.1 Administration, Temporary Buildings and Structures
The building official is authorized to issue a permit for temporary buildings or structures. Such permits shall be limited as to time of service ...