Temporarily unoccupied buildings, structures, premises or parts thereof, including tenant spaces, shall be secured and protected in accordance with this section.
311.2.1 Security
Exterior openings and interior openings accessible to unauthorized persons, including tenants, shall be locked or otherwise protected to prevent entry by unauthorized persons.
311.2.2 Fire Protection
Fire alarm, sprinkler and standpipe systems shall be maintained in an operable condition at all times, except as authorized by the commissioner.
311.2.3 Fire Separation
Fire-resistance-rated partitions, fire barriers, and fire walls, including those separating temporarily unoccupied tenant spaces from the remainder of the building shall be maintained. Openings, joints, and penetrations in fire-resistance-rated assemblies shall be protected in accordance with Chapter 7 of the Building Code.

Related Code Sections

§28-215.6 Enforcement, Closing Streets Temporarily
The commissioner may, when necessary for the public safety, temporarily close the sidewalks, streets, structures or places adjacent to a structure ...
§28-215.6 Enforcement, Closing Streets Temporarily
The commissioner may, when necessary for the public safety, temporarily close the sidewalks, streets, structures or places adjacent to a structure ...
§28-215.6 Enforcement, Closing Streets Temporarily
The commissioner may, when necessary for the public safety, temporarily close the sidewalks, streets, structures or places adjacent to a structure ...
Section 1209 Interior Environment, Access to Unoccupied Spaces
Crawl spaces shall be provided with not fewer than one access opening that shall be not less than 18 inches by 24 inches (457.2 mm by 609.6 mm). All ...