Tempered water shall be delivered from lavatories and group wash fixtures located in public toilet facilities provided for customers, patrons and visitors. Tempered water shall be delivered through an approved water-temperature limiting device that conforms to ASSE 1070/ASME A112.1070/CSA B125.70.

Related Code Sections

416.5 Fixtures, Faucets and Fixture Fittings, Tempered Water for Public Hand-Washing Facilities
Tempered water shall be delivered from public hand-washing facilities. Tempered water shall be delivered through an approved water-temperature ...
607.1 Water Supply and Distribution, Where Required
or building maintenance purposes. In nonresidential occupancies, hot water or tempered water shall be supplied for bathing and washing purposes. Tempered water ...
607.1 Water Supply and Distribution, Where Required
maintenance purposes. In nonresidential occupancies, hot water or tempered water shall be supplied for bathing and washing purposes ...