• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

320.4 Telephone and Data Equipment Rooms. [OSHPD 1 & 4]

California Mechanical Code 2016 > 3 General Regulations > 320.0 Air Conditioning and Heating Systems > 320.4 Telephone and Data Equipment Rooms. [OSHPD 1 & 4]
JUMP TO FULL CODE CHAPTER
Where telecommunications service entrance rooms, technology equipment centers, or technology distribution rooms are provided in accordance with Section 1224.5 of the California Building Code, the following requirements shall apply:

320.4.1

Power for HVAC systems serving the room(s) shall be supplied by the Equipment Branch pursuant to the California Electrical Code. Where redundant systems are provided, only one shall be required to be supplied by the Equipment Branch.

320.4.2

Mechanical equipment or fixtures that are not directly related to the support of the room shall not be installed in or pass through the room.

Exception: Unrelated ductwork may be installed and shall be not less than 10 feet (3048 mm) above the finished floor.

320.4.3

HVAC systems shall be provided to maintain environmental conditions recommended in ASHRAE's Thermal Guidelines for Data Processing Environment and the requirements of the specific equipment installed.

Related Code Sections


320.4 General Regulations, Telephone and Data Equipment Rooms. [OSHPD 1 & 4]
Where telecommunications service entrance rooms, technology equipment centers, or technology distribution rooms are provided in accordance ...
California Mechanical Code 2016 > 3 General Regulations > 320.0 Air Conditioning and Heating Systems > 320.4 Telephone and Data Equipment Rooms. [OSHPD 1 & 4]
310.13 General Regulations, Telephone and Data Equipment Rooms [OSHPD 1 & 4]
Where telecommunications service entrance rooms, technology equipment centers, or technology distribution rooms are provided in accordance ...
California Plumbing Code 2016 > 3 General Regulations > 310.0 Prohibited Fittings and Practices > 310.13 Telephone and Data Equipment Rooms [OSHPD 1 & 4]
(A) Special Occupancies, Equipment for Delayed Automatic Connection
equipment rooms and closets and data equipment rooms and closets. [OSHPD 1, 2, 3 (surgical clinics), 4 & 5] Equipment as required in the Essential ...
California Electrical Code 2019 > 5 Special Occupancies > 517 Health Care Facilities > 517.35 Equipment Branch Connection to Alternate Power Source > (A) Equipment for Delayed Automatic Connection
310.13 General Regulations, Telephone and Data Equipment Rooms
[OSHPD 1, 4 & 5]. Where telecommunications service entrance rooms, technology equipment centers, or technology distribution rooms are provided ...
California Plumbing Code 2019 > 3 General Regulations > 310.0 Prohibited Fittings and Practices > 310.13 Telephone and Data Equipment Rooms
310.13 General Regulations, Telephone and Data Equipment Rooms
[OSHPD 1, 4 & 5]. Where telecommunications service entrance rooms, technology equipment centers, or technology distribution rooms are provided ...
California Plumbing Code 2022 > 3 General Regulations > 310.0 Prohibited Fittings and Practices > 310.13 Telephone and Data Equipment Rooms
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING