• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2206.2.3.6 Tank Overfill Alarm

NYC Fire Code 2014 > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2206 Design and Installation Requirements for Liquid Motor Fuel-Dispensing Facilities > 2206.2 Method of Storage > 2206.2.3 Aboveground Tanks Located Outdoors, at Grade > 2206.2.3.6 Tank Overfill Alarm
JUMP TO FULL CODE CHAPTER
Tanks shall be provided with an approved overfill alarm in accordance with FC2206.2.1.6.

Related Code Sections


1305.7.2 Fuel-Oil Piping and Storage, Termination Location
pipe terminal location, an electronic overfill alarm system or a 1-inch (25.4 mm) tell-tale line shall be connected to the tank and shall parallel ...
NYC Mechanical Code 2022 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.7 Normal Vent Piping > 1305.7.2 Termination Location
1305.13.3 Fuel-Oil Piping and Storage, Above Ground; Above the Lowest Floor Inside a Building
of the New York City Building Code . To prevent overfilling of the containment barriers, sprinkler shut-offs shall be located on the outside of tank ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.13 Installation of Tanks > 1305.13.3 Above Ground; Above the Lowest Floor Inside a Building
1305.13.3 Fuel-Oil Piping and Storage, Above Ground; Above the Lowest Floor Inside a Building
and manual starting and stopping of the transfer pumps so as to prevent the overflow of oil from these storage tanks.   7. Indicators and alarms ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.13 Installation of Tanks > 1305.13.3 Above Ground; Above the Lowest Floor Inside a Building
415.6.2.6 Special Detailed Requirements Based on Use and Occupancy, Leakage Alarm
An approved automatic alarm shall be provided to indicate a leak in a storage tank and room. The alarm shall sound an audible signal, 15 dBa above ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.6 Group H-2 > 415.6.2 Flammable and Combustible Liquids > 415.6.2.6 Leakage Alarm
415.7.2.6 Special Detailed Requirements Based on Use and Occupancy, Leakage Alarm
An approved automatic alarm shall be provided to indicate a leak in a storage tank and room. The alarm shall sound an audible signal, 15 dBa above ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.7 Group H-2 > 415.7.2 Flammable and Combustible Liquids > 415.7.2.6 Leakage Alarm
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING