• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1417(f) Tag-Out

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1417 Operation > 1926.1417(f) Tag-Out
JUMP TO FULL CODE CHAPTER

1926.1417(f)(1) Tagging Out of Service Equipment/Functions

Where the employer has taken the equipment out of service, a tag must be placed in the cab stating that the equipment is out of service and is not to be used. Where the employer has taken a function(s) out of service, a tag must be placed in a conspicuous position stating that the function is out of service and is not to be used.

1926.1417(f)(2) Response to "Do Not Operate"/Tag-Out Signs

1926.1417(f)(2)(i)

If there is a warning (tag-out or maintenance/do not operate) sign on the equipment or starting control, the operator must not activate the switch or start the equipment until the sign has been removed by a person authorized to remove it, or until the operator has verified that:

1926.1417(f)(2)(i)(A)

No one is servicing, working on, or otherwise in a dangerous position on the machine.

1926.1417(f)(2)(i)(B)

The equipment has been repaired and is working properly.

1926.1417(f)(2)(ii)

If there is a warning (tag-out or maintenance/do not operate) sign on any other switch or control, the operator must not activate that switch or control until the sign has been removed by a person authorized to remove it, or until the operator has verified that the requirements in paragraphs (f)(2)(i)(A) and (B) of this section have been met.

Related Code Sections


1926.1417(f) Cranes & Derricks in Construction, Tag-Out
Where the employer has taken the equipment out of service, a tag must be placed in the cab stating that the equipment is out of service ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1417 Operation > 1926.1417(f) Tag-Out
1926.1430(f) Cranes & Derricks in Construction, Tag-Out
(such as maintenance and repair employees), in the tag-out and start-up procedures in § § 1926.1417(f) and (g) ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1430 Training > 1926.1430(f) Tag-Out
1926.1417(f)(2) Cranes & Derricks in Construction, Response to "Do Not Operate"/Tag-Out Signs
If there is a warning (tag-out or maintenance/do not operate) sign on the equipment or starting control, the operator must not activate the switch ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1417 Operation > 1926.1417(f) Tag-Out > 1926.1417(f)(2) Response to "Do Not Operate"/Tag-Out Signs
1926.555(a)(7) Helicopters, Hoists, Elevators, and Conveyors,
Conveyors shall be locked out or otherwise rendered inoperable, and tagged out with a "Do Not Operate" tag during repairs and when operation ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.555 Conveyors > 1926.555(a) General Requirements > 1926.555(a)(7)
1926.1415(a)(7)(ii) Cranes & Derricks in Construction,
If a built-in horn is not working properly, it must be tagged-out or removed. If a removable horn is not working properly, it must be removed ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1415 Safety Devices > 1926.1415(a) Safety Devices > 1926.1415(a)(7) Horn > 1926.1415(a)(7)(ii)
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING